TOWER 10 AM, TOWER 12 AM [GRADE 3]
English
Anti-Masking PIR and Dual technology (PIR/MW) Mirror Detectors - Installation
instructions
Detectores de espejo (PIR/MW) Doble Tecnología y Anti-Masking
Español
Detectores de Espelho PIR e Dupla Tecnologia (PIR/MW) Anti-Mascara.
Portuguese
Instruções de Instalação
ENGLISH
1. INTRODUCTION
The TOWER 10 AM PIR and TOWER 12 AM Dual Technology are professional
vandal resistance Anti-Masking detectors designed for large commercial and
industrial applications providing wide coverage with superior resistance to harsh
environment, employing several revolutionary patented technologies
Features:
 V-slot recessed small window technology (patent pending) for extreme
mechanical robustness and protection from false alarms (patent pending).
 "Obsidian Black Mirrors"™ and "Elliptic / Parabolic Mirror" technology
providing over 15,000 LUX resistance to white light and multiple-solid curtain
pattern with 50% better sensitivity than comparable mirror optics (several
patents pending).
 Adaptive Active Infra-Red Anti-Masking technology providing the most
advanced reliable protection against intentional masking attempts (patent
pending).
 Optional interchangeable Long-Range Curtain mirror providing 35m x 2.5m
(115ft x 8.2ft) coverage for TOWER-10 and 25 x 2m (82 x 6.5ft) coverage for
TOWER-12.
 Installer friendly features:
Built-in selectable E.O.L. resistors for alarm, trouble and tamper outputs.
Plug-in terminals attached to base for easy pre-wiring.
Unique sliding closing mechanism with captive screw.
Extended mounting height 1.5 - 4m (5 - 13 ft.).
Low supply voltage indication.
Remote controlled walk-test input.
Optional mounting brackets.
Selectable range adapted to the protected area size by use of a Range
Selector (TOWER 12 AM).
 Microprocessor controlled, digital TMR signal processing with dual-slope digital
temperature compensation.
 Front and Back tamper.
 True "Creep zone" down looking optics.
 Pet immunity (18Kg/40lb) using a special "pet mask".
 Built-in auto diagnostic for both PIR and microwave detectors.
2. SPECIFICATIONS
OPTICAL
Wide Angle
TOWER 10 & 12
coverage
25mx30m / 90º
Far Field Of View (FOV)
Medium FOV
Event counter settings
Mounting:
Method: Surface, corner or at 45º to wall.
Height: 1.5 - 4m (5-13 ft.) without bracket.
Vertical adjustment: Angled base surface provides three tilt adjustments
according to mounting height and coverage range.
ELECTRICAL
Sensors type:
PIR: dual element low noise pyroelectric sensor.
MW: X-Band Doppler module.
For UK - 10.687 GHz, for EU / USA – 10.525 GHz. For
German/Czech 9.35 GHz
Supply voltage: 8 – 16 VDC.
NOTE: Unit shall be powered only by Limited Power Source (marked "LPS")
certified power supply
Low voltage detection: If input voltage is below 7.5 VDC.
Supply current:
Standby @ 12 VDC: 12mA (TOWER 10 AM). 15 mA (TOWER 12).
Maximum: 14mA (TOWER 10 AM). 18 mA (TOWER 12).
Alarm period: 2 to 3 sec.
Masking detection delay: 30 sec.
Remote LED enable input (TST): High impedance input. Affects LEDs
operation only if internal LEDs selector is set to OFF.
Outputs:
Alarm output: Solid State Relay. NC, 100 mA / 30 V, 35 ohm maximum
D-300909 TOWER 10 AM/TOWER 12 AM Installation Instructions
.
Mirror Types (see Fig. 2)
Long Range Curtain
TOWER 10
TOWER 12
35m / 5º
11 curtains
1 curtain
6 curtains
1 curtain
1 or 2
LR
internal resistance. "Open" for 2 – 3 sec. in case of alarm, masking event or
complete power failure.
Trouble output: Solid State Relay. NC, 100 mA / 30 VDC, 35 ohm
maximum internal resistance. "Open" in case of auto-diagnostic failure, Anti-
Mask event, low voltage or complete power failure.
Tamper output: NC switch, 50mA / 30 VDC. "Open" by opening detector's
cover or removing it from mounting surface.
Built-in End Of Line resistors circuit: Selectable serial resistors for each of
the three outputs. Resistors values: 0 Ohm (Factory default), 1K, 2.2K, 4.7K,
5.6K Ohm (see figure 5).
LED indications:
Event / status
Low voltage
Warm-up (60sec.)
Self-test failure
AM detection
ALARM
PIR detection
MW detection
Warm-up time: 60 sec.
ENVIRONMENTAL
Operating Temperature: –20°C to 55°C (-4°F to 131°F).
Storage Temperature: –20°C to 60°C (–4°F to 140°F)
RFI Protection: Greater than 20 V/m (up to 2 GHz).
Housing: IP41 and IK04 .
Dimensions: 160x77x47mm (6-5/16 x 3 x 1-13/16 in.)
Optional ACCESSORIES:
BR-1: Surface mounted swivel bracket, adjustable 30° down and 45° left/45°
right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
CURTAIN-10/12: Interchangeable long range 35m/5° curtain mirror
PET-10/12: Pet mask provides 18Kg/40Lb pet immune for wide angle mirror
only.
Standards:
Designed to comply with EN50131-1 Grade 3 / Class II, EN50131-2-2,
EN50131-2-4, EN300440, EN301489, EN60950.
Belgium standard TO14.
Sweden standard: SSF 1014.
25m / 5º
3. INSTALLATION
3.1 General Guidance
(See figure 3)
3.2 Installation Procedure
(See figure 4 & 5).
3.3 Jumpers setting
3.4 Long Range Mirror mounting
Optional for TOWER-10 AM - See figure 6. For long range mirror, the COUNT
(counter) jumper should be set to "LR" position (see fig. 5).
3.5 Pet Mask Mounting (optional)
For pet immunity (up to 18Kg/40lb), a special "pet mask" model PET 10/12 should
be mounted on the mirror (see figure 6, step 4a).
3.6 Test
A. Power up the system. The LEDs will flash alternately, indicating that the
detector is adapting itself to its present surroundings. Stay at least 1m
(3ft) away from the detector, until the 60 seconds startup period ends
(until the LEDs stop flashing alternately).
B. Enter the detector's field of view and perform walk test in the entire
coverage area, while observing the red LED (see figure 2). For TOWER 12,
observe also the green LED for MW and PIR detections (see "LED
indications" table in the specifications). The red LED will light for 2-3
seconds each time the alarm output is activated (see figure 2).
Important! Instruct the user to perform walk test at least once a week to
EN: Yellow, red & green LEDs
SP: LEDs amarillo, rojo y verde
PT: LEDs amarelo, vermelho e verde
Figure 1 - TOWER 10 AM / TOWER 12 AM
Indication
TOWER 12
TOWER 10 AM
Red flashing
Yellow + Red + Green
Yellow + Red
flashing alternately
flashing alternately
Yellow + Red flashing simultaneously
Yellow ON
Red ON
Green flashing
Green ON
(See figure 5)
---
---
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Visonic TOWER 10 AM

  • Página 1 1. INTRODUCTION complete power failure. The TOWER 10 AM PIR and TOWER 12 AM Dual Technology are professional Trouble output: Solid State Relay. NC, 100 mA / 30 VDC, 35 ohm maximum internal resistance. "Open" in case of auto-diagnostic failure, Anti- vandal resistance Anti-Masking detectors designed for large commercial and Mask event, low voltage or complete power failure.
  • Página 2: Introducción

    1. INTRODUCCIÓN NOTA: La unidad estará alimentado sólo por fuente de alimentación limitada TOWER 10 AM PIR y TOWER 12 AM Doble Tecnología, son detectores (marcado" LPS ") fuente de alimentación certificada. profesionales anti-vandálicos y Anti-Masking, diseñados para su utilización en Detección de Baja tensión: Si la tensión es inferior a 7.5 VDC.
  • Página 3: Montaje Con Inmunidad A Mascotas (Opcional)

    1. INTRODUÇÃO Montagem: Método: Superfície, canto ou a 45º. O TOWER 10 AM PIR e o TOWER 12 AM são detectores de dupla tecnologia Altura: 1.5 - 4m (5-13 ft.) sem suporte. Anti-Mascara profissionais resistentes ao vandalismo, desenhados para Ajuste Vertical: Base com superfície angular proporciona três ajustes de aplicações comerciais e industriais com grande cobertura, resistência superior em...
  • Página 4: Comentários Especiais

    TOWER 12, observe também o led verde para a detecção MW e PIR (ver Directiva 2002/96/EC Lixo de Equipamentos Eléctricos e Electrónicos. "tabela indicações LED" nas especificações). O led vermelho é activo durante D-300909 TOWER 10 AM/TOWER 12 AM Installation Instructions...
  • Página 5 SP: Agujeros para tornillos de tamper trasero sin conos (para mayor robustez). PT: Orifício para parafuso do tamper traseiro – sem cone (para adicionar força) Fig. 4 - Mounting / Montaje/ Montagem D-300909 TOWER 10 AM/TOWER 12 AM Installation Instructions...
  • Página 6 Figure 6 - TOWER-10 AM Long Range Mirror and Pet Mask Replacement / Espejo Largo Alcance TOWER 10 AM y sustitución de filtro antimascota / Espelho Longo Alcance TOWER 10 AM e recolocar mascara animal. TOWER 10 - 1 AM, TOWER 12 - 1 AM EN: ALARM CONTROL PANEL.

Este manual también es adecuado para:

Tower 12 am

Tabla de contenido