Before You Begin
Tools and Parts Needed
Phillips Head Screwdriver
▯
Precision Flathead Screwdriver
▯
Tape Measure
▯
Teflon Tape (Gas Rated)
▯
Adjustable Wrench or Channel Lock Pliers
▯
Parts Included
Foam Tape
▯
Mounting Brackets (4)
▯
Screws, #10-32 x 2 1/2" (63.8 mm) (4)
▯
Sheet Metal Screws, #8 x 3/8" (9.5 mm) (4)
▯
Washers (4)
▯
Burner Grates (3)
▯
Burners
▯
30" models: (4) or (5)
▯
36" models: (5)
▯
Burner Caps
▯
30" models: (4) or (5)
▯
36" models: (5)
▯
Pressure Regulator
▯
LP Gas Conversion Kit
▯
Note: If parts are missing or damaged, call the number
or write to the address listed on the inside back cover.
General Information
Overall Dimensions
Width (Side to Side)
Depth (Front to Back)
Height (Top to Bottom)
Note: These are overall dimensions NOT cutout
dimensions.
6
30" Models
36" Models
31"
37"
(788 mm)
(940 mm)
21 1/4"
21 1/4"
(540 mm)
(540 mm)
3 13/16"
3 13/16"
(97 mm)
(97 mm)
Preparation
Electrical Requirements
CAUTION
9
Do not use an extension cord with the gas cooktop.
This appliance requires a 60 Hz, 15 Amp, 120 VAC
connection. Plan the installation so that the power
connection is accessible from the front of the cabinet.
Gas Requirements
Supply Pressure:
Natural Gas: 7 inches water column (14.9 Millibars)
▯
Propane Gas: 11 inches water column (27.4 Millibars)
▯
The propane gas tank must be equipped with its own
high pressure regulator in addition to the pressure
regulator supplied with this unit. The cooktop is shipped
from the factory for use with natural gas. For use with LP
conversion, a certified technician or installer must do the
conversion.
Cabinet Requirements
Depth from Back Wall
Cabinet 13" (330) max.
Centered over cooktop
NGM30 - min. 30" (762)
NGM36 - min. 36" (914)
Above counter - min. 30" (762)
to combustible surface
min. 18" (458)
Rear wall - 2" (51mm)
Left Side
min. 12" (305)
Instructions are based on standard American cabinets
▯
36" high (91cm) x 24" deep (61cm) with a 25"
(63cm) countertop.
The maximum depth of a cabinet installed above the
▯
cooktop is 13" (33cm).
Note: All measurements given must be precisely
followed. If nonstandard cabinets are used, make sure
they are installed with minimum dimensions shown.
Plan the installation of the unit so that the power cord,
gas shut-off valve and gas pressure regulator are
accessible from the front of the cabinet.
Right Side
min. 12" (305)
( )=mm