Water Filtration System Performance Data Sheet
a healthy home experience
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42 and 53
for the reduction of the substances listed below and NSF/ANSI 372 for low lead compliance. The
concentration of the indicated substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance
NSF/ANSI 42
Aesthetic Effects
NSF/ANSI 53
Health Effects
While testing was performed under standard laboratory conditions, actual performance may vary.
Rated Capacity:
Min-Max operating pressure:
Min-Max feed water temperature:
Rated Service Flow:
•
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
•
Refer to the owner's manual for specific installation instructions, manufacturer's limited warranty, user
responsibility, and parts and service availability.
•
For parts and service availability, please contact Brondell.
•
The estimated replacement time of filter, which is a consumable part, is not an indication of quality
guarantee period, but it means the ideal time of filter replacement. Accordingly, the estimated time of filter
replacement may be shortened in case it is used in an area of poor water quality
Model of Filter
HF-31
HF-32
HF-33
16
Minimum
Percent
Reduction
Chlorine, Taste & Odor
98.0%
Particulate, Class I particles
91.3%
0.5 to < 1 m
Turbidity
VOCs
Influent challenge
Concentration
(mg/L unless specified)
2.00 ± 10%
at least 10,000 particles/mL
96.6%
11 ± 1 NTU
3.00 ± 10%
99.9%
5,000 gallons for aesthetic chlorine and 150 gal for VOC's
20 ~ 120 psi (207 kPa ~ 827 kPa)
40 ºF ~ 100 ºF (4.4 ºC ~ 37.8 ºC)
0.5 gpm (1.9 LPM)
Type
Composite Plus Filter
Nanotrap Filter
Carbon Block Filter
Model: Cypress H630
Maximum permissible
Product water Concentration
or minimum allowable
% reduction
(mg/L unless specified)
≥50% Reduction
≥85% Reduction
0.5 NTU
≥95% Reduction
Usable period
6 months
12 months
6 months