Installation
The heat pump must be installed outdoors at least 3.5m from the pool in
accordance with current regulations (NF C 15 100).
Install the heat pump on a stable and hard horizontal surface (a concrete
slab may be provided).
Maintain 1 m of unobstructed space in front of the vertical air intake grilles
and 3 m of space for the fan outlet.
Be sure to leave enough space to access the temperature control.
Ensure that the discharged air will not be drawn back into the heat pump.
To complete your installation
Avoid directing the ventilated air flow toward a location that may be susceptible to
noise (a bedroom window, for example).
Avoid installing the heat pump on a surface that may transmit vibrations to your
home.
In order to keep maintenance to a minimum, avoid placing the heat pump under
a tree or in a location where it may be splashed with water or mud.
Security
Do not install the heat pump near a flammable gas source.
Keep the apparatus out of the reach of children.
To prevent accidents, children and household pets should be prevented from
accessing the apparatus. Do not cover the unit while it is in operation or insert
fingers or objects inside.
This electrical device must be installed by a qualified/certified electrician, in
compliance with standard NF C 15 100.
Never operate the apparatus without all its body elements in place.
Hydraulic connections
Connect the swimming pool's water inlet and outlet as indicated by the labels
on the machine (inlet
diameter as required) with the removable connectors supplied with the heat
pump.
The unit can be connected via a by-pass on the filtration system after the
filtering element and before water treatment (see diagram after).
For a direct water supply connection, contact your dealer.
Maximum water supply pressure in operation: 2 bar
and outlet
) using Ø50 PVC pipe (or larger
28