Settings

Operation table
On/off
LED
switch
Key:
LED illuminated
LED off
Digital
Fan
controller
Does not
Does not
operate
operate
Does not
Does not
operate
operate
Does not
operate
Does not
operate
In
operation
In
operation
Does not
operate
Meaning
The heat pump
is not
connected to
an electrical
power supply
The relay is not
well connected
off
Temperature reached
off
Start-up time
blink
delay
Defrosting in
light
progress
light
The machine is operating normally
off
-
35
Action
Check the
electrical
connections
Check the
electrical
connections
Wait 2 minutes
Wait until
defrosting is
completed
Faulty fan