Napa CARLYLE DAMM Instrucciones De Operación página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

STEP 4: PRE-TIGHTEN WRENCH
Hold on your wrench to pre-tighten the screw.
(eliminate the backlash of wrench)
STEP 5: START TO MEASURE ANGLE
Press
to start the angle meter and immediately
begin your angle torque measurement.
STEP 6: STOP AND WAIT FOR LCD FLASHING TO MEASURE ANGLE
Press
When measuring angle, if a long pause is detected
by the meter, then the LCD screen will begin to
flash, and it will hold the angle it recorded right
before the pause. You will need to press
the screen and press
Note:
1. There are 6 LEDs to indicate the current angle
reaching 80%, 85%, 90%, 95%, 97.5% and 100%
of target angle.
2. There is also a buzzer to indicate reaching
level of target value. The interval sound means the
meter has reached 80% of the target angle. The
extended sound means you have surpassed 100%
of the set target angle.
DAMM
Pre-tighten
Press
to clear
to resume.
100%
97.5%
((...((...
((((((((...
6
Flashing
95%
90%
85%
...))...))
over 80%
...))))))))
over 100%
80%
Rev. 02/17/12