Descargar Imprimir esta página

Siemens Intrunet E-Line ADM-I12W1 Manual Del Usuario página 3

Ocultar thumbs Ver también para Intrunet E-Line ADM-I12W1:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
Instruction
en
ADM-I12W1 motion detector
The detector detects movement in the
room under surveillance
an alarm. It responds most sensitively to
movement in the directions indicated by
arrows
7
B / D. The alarm is transferred
by wireless. The back tamper recognizes
if the detector is removed with force.
Prerequisites
The detector should be installed by peo-
ple with specialist knowledge and in
compliance with valid regulations.
The detector is only intended
for indoor use. Note the posi-
tioning instructions
Opening the detector
1. Check the scope of delivery
2. Slide up the screw-on cover
loosen the screw
2
B.
3. Pull the housing front
2
2
C.
Fitting the detector
1. Fit the mounting base
- Define type of fastening
refer to mounting bracket option)
- Break open three fixing holes.
- Fit mounting base at the proposed
height.
The mounting base should be
secured using two screws
A / B and the back tamper
with one screw
2. Pull out insulation strip between bat-
tery and bracket
8
A.
3. Press the tamper contact
ter the detector with the system.
For safety reasons only use
the battery supplied and not
any other type.
2
4. Fold front
D back onto mounting
base
2
C and secure with screw
Slide down screw-on cover
Programming
To adjust the settings to the application,
5
move the switches
A into the corre-
sponding positions:
Switch
Function
1
LED
2
Sensitivity
3
Auto Power Save
4
Pet Immunity
* Factory Setting
Sensitivity setting
5
D
Turn potentiometer
into the position required to
adjust detector to room size
and field of vision.
* Factory setting is the middle position
(12-meter field of vision)
Potentiometer settings other than the
centre (factory) position are not certi-
7
and initiates
fied by Telefication for EN compliance
and will result in a different coverage
area.
ID registration
You will find instructions for integrating
the detector in the control panel in the
control panel's installation manual.
Walk test
1. Call up walk test mode in the control
panel.
2. Hold a magnet to the right of the de-
tector for 1 second
3. Run the walk test for alarm triggering
6
.
in the whole detection area
detector.
1
.
Alarm transmission test
2
A and
1. Call up walk test mode in the control
panel.
D off the base
2. Hold a magnet to the right of the de-
tector for at least 2 seconds
3. The alarm transmission test has now
2
C as follows:
started. 11 test signals are sent to the
4
A / B. (also
control panel at an interval of 6 sec-
onds (the LED
transmission).
4. The test is passed if the control panel
receives the test signals and indicates
this accordingly.
4
Options
Narrow angle lens kit AO-C25
4
C.
The kit enables the detection area cov-
erage to be defined to a narrow angle as
shown in
Loosen the lens currently at the positions
5
B to regis-
shown in
tector. Insert adapter
and press down narrow angle lens.
White light filter AO-WL10k*
The white light filter is needed for appli-
cations with extreme white light interfer-
ence (> 4000 lux).
2
B.
Loosen the lens currently at position
2
A.
and remove this from the detector. Insert
adapter
lens back down.
* Note: Not certified by Telefication for
EN compliance.
ON
OFF
Wall & ceiling mounting brackets
*On
Off
The mounting brackets AZ-MBG2
*Low
High
(ceiling
*On
Off
be used to swivel the detector ±45°.
25kg
*15kg
Maintenance and Service
Check the detector regularly (at least
once a year) to ensure that it is function-
5
D
ing correctly (by carrying out a walk test),
that it is free of dirt, and that it is securely
attached. If necessary, clean and /or se-
cure the detector.
8
B.
7
of the
8
B.
10
flashes during each
7
D.
5
F and remove from the de-
3
C in to detector
3
B in to detector and press the
9
B and wall
9
C mounting) can
- 3 -
Technical data
Detection area
coverage
wide angle
7
B
Detection area
coverage
narrow angle
7
D
Range of wireless
module
Frequency:
ADM-I12W1
Identification
Data protocol
Event transmission
Test mode
Battery power sav-
ing
Battery
Low battery
threshold
Current
consumption
Warm up period
Pet immunity
EMI rejection up to
2 GHz
Operating tempera-
ture
Storage tempera-
ture
Air humidity
EN 60721
Type of housing
protection
EN 60529,
EN 50102
5
F
Siemens Security Products hereby de-
clares that this product is in compliance
with the essential requirements and other
relevant provisions of Directive 1999/5/EC
on Radio and Telecommunications Ter-
minal Equipment (R&TTE) and
2004/108/EC on Electromagnetic Com-
9
patibility (EMC).
9
A
The EC Declaration of Conformity is
available from your Siemens sales office
or:
Siemens AB, Security Products, En-
glundavägen 7, SE-171 24 Solna, Swe-
den
en
12 m
20 m
Up to 300 m out-
doors
868 MHz
ID serial number
24 bits
SiWay
Alarm, sabotage,
surveillance, bat-
tery low
Walk test & alarm
transmission test
Automatic energy
saving function
Lithium 3 V
Type: xx123
Size: 2/3 AA
Capacity: 1550mAh
2.4 V
Standby 28 μA
Max. peak 36 mA
60 ±5 s
<15 kg
<25 kg
>10 V/m
-10 °C...+50°C
-20 °C...+60 °C
<85 %rF, not
condensing
IP41 / IK02

Publicidad

loading