Warnings; Chemical Spills; In Case Of Fire; Cylinder Warranty - ICP HANDI-FOAM Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNINGS

Consult the product's SDS (included in shipping packet attached to the A-cylinder) for specific information. The urethane foam produced from these ingredi-
ents will support combustion and may present a fire hazard if exposed to a fire or excessive heat above 240°F (116°C). For professional use only.
WARNING: Non-Flammable Compressed Gas. Keep away from heat. Smoking and open flames, including hot work, should be prohibited in the vicinity
of a foaming operation. Avoid contact with skin and eyes. May cause sensitization by inhalation and/or direct skin contact. Avoid prolonged or repeated
breathing of vapor. Wear protective glasses with side shields or goggles, nitrile gloves, and clothing that protects against dermal exposure. Use only in a
well-ventilated area with certified respiratory protection or a powered air purifying respirator (PAPR). KEEP OUT OF REACH OF CHILDREN.
FIRST AID: In any first aid case CONSULT A PHYSICIAN. EYES: Flush with water for at least 15 minutes. SKIN: Remove contaminated clothing. Wash
skin with plenty of soap and water. Cured foam must be removed manually. INHALATION: If breathing is difficult, give oxygen. If breathing has stopped,
give artificial respiration. INGESTION: Give large quantities of water. Do NOT induce vomiting. Contact a physician immediately in any first aid situation.
Consult the product's SDS (included in Shipping Packet attached to the A-cylinder) for specific information. Contents: polymeric diisocyanate, fluorinated
hydrocarbon blowing agent, polyol, amine catalyst.

CHEMICAL SPILLS

• If liquid spills from the A-component cylinder, provide ventilation and isolate the area. Wearing protective equipment, soak up the spill with an oil
absorbent material such as vermiculite or sawdust. Place the material in an open container. Do not seal the container. Allow the loosely covered
container to stand for several days before disposing in accordance with all applicable federal, state and local regulations consistent with good industrial
practice.
• Decontaminate the waste and spill area with a solution of 0.2-0.5% liquid detergent and 3-8% concentrated ammonium hydroxide in 90-95% water
(5-10% sodium bicarbonate or baking soda may be substituted for bleach). Use 10 parts of solution for each part of spill and allow the decontaminating
solution to react for several hours.
• If liquid spills from the B-component cylinder, soak up the spill with oil absorbent material and dispose of in accordance with all applicable federal, state
and local regulations. Wash the spill area thoroughly with soap and water.
• Consult Safety Data Sheet (SDS), for accidental release measures and disposal considerations. In case of transportation emergency 24 hour day, contact
CHEMTREC 1 800.424.9300.

IN CASE OF FIRE

• Responder must wear full emergency equipment including self-contained breathing apparatus.
• Use dry chemical, carbon dioxide, foam or large amounts of water spray (do not use direct spray) to control fire.
• Use water spray to cool exposed containers and reduce risk of rupture.

CYLINDER WARRANTY

TO MAINTAIN WARRANTY, DO NOT MAKE ANY CHANGES OR ADJUSTMENTS TO THE CYLINDER OR Cylinder COMPONENTS, IN-
CLUDING PLUMBING.
ICP Adhesives & Sealants, Inc. warrants that the cylinder is fit to dispense ICP's foam products that are loaded into the cylinder by ICP Adhesives & Seal-
ants, Inc. OTHER THAN THAT WARRANTY, ICP MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES AND ICP SPECIFICALLY DISCLAIMS ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTY OF MECHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The sole remedy for any breach of war-
ranty is replacement of the cylinder. ICP Adhesives & Sealants, Inc. IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. The terms, condi-
tions and warranties applicable to ICP Adhesives & Sealants, Inc. dispensed from the cylinder are covered in other ICP Adhesives & Sealants, Inc. documentation
relating to that purchase. Buyer must not make any changes to the cylinder or the cylinder components, including plumbing. Any such change may produce
dangerous results and cause damage or injury, including a loss of product stored in the cylinder. ICP Adhesives & Sealants, Inc. is not responsible for damages
or injuries resulting from any such changes. Those damages or injuries are Buyer's responsibility, and ICP Adhesives & Sealants, Inc. may charge Buyer for the
costs of any resulting cylinder damage or repairs. ICP Adhesives & Sealants, Inc. also reserves the right to restrict future sales if the Buyer does not address safety
concerns such as modified or missing plumbing, pressure relief valve activated or excessive cylinder pressure.

MAGNUM HEATED HOSE WARRANTY

ICP Adhesives & Sealants, Inc. makes no warranty regarding the hose. However, the hose Manufacturer warrants that the hose will be free from defects in
materials and workmanship for a period of one year from the date of purchase. Manufacturer will repair or replace, as Manufacturer may elect, the hose or
any component part found, upon inspection by Manufacturer, to be defective in material or workmanship during that period. This is the sole warranty rem-
edy available to Buyer. This warranty applies only when the hose is installed, operated and maintained in accordance with training, operating instructions
and user guidelines.
Buyer must report any warranted defect to ICP Adhesives & Sealants, Inc. in writing within 10 days of discovery, permit ICP Adhesives & Sealants, Inc. and
Manufacturer to inspect the defective part and, if requested by ICP Adhesives & Sealants, Inc. or Manufacturer, ship the defective part at Buyer's cost, to
Manufacturer or ICP Adhesives & Sealants, Inc. This warranty does not cover, and Manufacturer shall not be liable for, general wear and tear, or any malfunc-
tion, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering,
or substitution of component parts. Buyer's exclusive remedy as to any breach of warranty, negligence or other claim shall be limited to the repair or replace-
ment of the equipment.
Failure to strictly adhere to any recommended procedures will terminate the warranty.
NEITHER ICP Adhesives & Sealants, Inc. NOR MANUFACTURER WILL BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES RELATING
DIRECTLY OR INDIRECTLY TO THE HOSE OR ITS USE.
THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

DISCLAIMER

Handi-brand
low pressure one-component polyurethane foam sealants and adhesives (OCF), low pressure spray polyurethane foams (SPF), and low pressure pour-in-place
®
polyurethane foams (PIP) are composed of a diisocyanate, hydrofluorocarbon or hydrocarbon blowing agent, and polyol. For polyurethane foam sealants/adhesives: wear
protective glasses with side shields or goggles, nitrile gloves, and clothing that protects against dermal exposure. Use only in a well-ventilated area. Avoid breathing vapors. Read
the SDS and instructions carefully before use (www.icpadhesives.com). For spray polyurethane foams and pour-in-place polyurethane foams: wear protective glasses with side
shields or goggles, nitrile gloves, and clothing that protects against dermal exposure. Use only in a well-ventilated area and with certified respiratory protection or a powered air
purifying respirator (PAPR). Additional information on ventilation can be found in the Handi-brand
(www.icpadhesives.com) and instructions carefully before use. The urethane foam produced from these ingredients will support combustion and may present a fire hazard if
exposed to a fire or excessive heat about 240°F (116°C). Refer to each product's TDS for specifications, testing results, and other attributes. The customer is ultimately responsible
for deciding whether products and associated TDS information are appropriate for customer's use. Refer to the products' SDS, the Handi-brand
and operating instructions for guidance on the safe and proper application of the product (www.icpadhesives.com). For professional use only. Building practices unrelated to
materials can lead to potential mold issues. Material suppliers cannot provide assurance that mold will not develop in any specific system.
14
Product Stewardship Guidelines (www.icpadhesives.com). Read the SDS
®
Product Stewardship Guidelines,
®

Publicidad

Tabla de contenido
loading

Tabla de contenido