Refill Systems 17 & Up With A Magnum Heated System; Setup - ICP HANDI-FOAM Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

REFILL SYSTEMS 17 & UP WITH A MAGNUM HEATED SYSTEM
Nitrogen Regulator
Red Nitrogen Hose
2
with Coupling (A)
11
Shipping Packet
(inside the collar
of the A cylinder)
6
A-Side On/Off
Valve, Cylinder to
Hose Filter with
Temperature
Gauge Assembly*
* Some accessories may require additional adapters.
Prior to proceeding with setup, please review all instruction manuals, hose tag instructions and labels.
1. Verify chemical temperature is between 70–85°F (21–29°C), see TDS for product specific process (core)
chemical temperature recommendations.
2. Before/during the system start-up process update the Daily Spray Log (A18013).
3. Attach the Nitrogen Regulator (#1) to the nitrogen bottle. Tighten fitting with a wrench.
4. Attach the
A-Side Red
Tighten fitting with a wrench.
5. Attach the Quick Disconnect on the
Valve (#4).
6. Attach the B-Side Nitrogen Hose with Coupling (#3) to the B-Side Cylinder Nitrogen Regulator (#1).
Tighten fitting with a wrench.
7.
Attach the Quick Disconnect on the B-Side Nitrogen Hose with Coupling (#3) to the Nitrogen On/Off Valve (#4).
8. Attach the Gun Hose Assembly (#9 or #13)
Tighten fitting with a wrench.
9. Attach the Gun Hose Assembly (#9 or #13) Black Striped Hose to the Magnum Hose (#10). Tighten fitting with
a wrench.
10. Ensure the Handi-Gun
engaged when trigger is released.
11. Remove the Cap (A cylinder) and Plug (B cylinder) from the Cylinder Outlet On/Off Valve (#5).
12. Attach the A-Side On/Off Valve, Cylinder to Hose Filter with Temperature Gauge Assembly (#6) to the
Cylinder Outlet On/Off Valve (#5) on the
13. Attach the B-Side On/Off Valve, Cylinder to Hose Filter with Temperature Gauge Assembly (#7) to the
Cylinder Outlet On/Off Valve (#5) B-cylinder. Tighten fitting with a wrench.
14. Open Ball Valves #5, #6, #7 and #8.
15. Plug the Heated Hose into a 120V grounded receptacle.
NOTE: Use of petroleum jelly (provided in nozzle packs) on all fittings will help prevent moisture contamination
on any exposed surfaces.
Storage Temperature
Optimum 75–85°F (24–29°C)
but not < 60°F or > 90°F
(not <16°C or >32°C)
Nitrogen Bottle
1
4
Nitrogen
On/Off Valve
Cylinder Outlet
On/Off Valve
5
A
B
7
B-Side On/Off Valve, Cylinder
to Hose Filter with Tempera-
ture Gauge Assembly*
Nitrogen Hose with Coupling (#2) to the A-Side Cylinder Nitrogen Regulator (#1).
A-Side Red
A-Side Red
Trigger Safety is engaged. The Handi-Gun II
®
A-Side
Process (Core)
Chemical Temperature
70–85°F (21–29°C)

SETUP

®
• Operating Instructions, Daily Spray Log & Bill of Lading are located in the
Shipping Packet inside the A-side cylinder collar.
• The Magnum Heated System
Magnum Heated hose.
Nitrogen Hose
3
with Coupling (B)
Hose to Gun
On/Off Valve
Assembly
8
10
Magnum Heated
System
Hose Assembly
®
Nitrogen Hose (#2) to the
Striped Hose to the
(#13) Trigger Safety is automatically
TM
Cylinder. Tighten fitting with a wrench.
Outside Application
Temperature
40—100°F (4–38°C)
Hose Care Instructions are attached to the
®
10" (25 cm)
Handi-Gun
ColorWise
Nozzle
®
Hose Assembly
(Cone or Fan)
9
12
Handi-Gun
®
Trigger Safety
OR
ColorWise
Nozzle
®
14
(Long Cone or Fan)
Hi
Lo
13
Handi-Gun II
Hose Assembly
Handi-Gun II
TM
Trigger Safety
A-Side Red
Nitrogen On/Off
A-Side Red
Magnum Hose (#10).
Surface Temperature
40—100°F (4–38°C)
®
TM
5

Publicidad

Tabla de contenido
loading

Tabla de contenido