Set the range selector switch [3] to the desired range in the DC voltage measuring range V
you do not know the voltage, first set the highest possible measuring range and then reduce it
gradually to the lower ranges until you obtain a satisfactory measurement result.
Connect the test probes [6] to the test object.
The measurement result is then indicated on the display [1]. A negative sign is indicated in front of
the measured value for a negative measurement result.
7.3 AC voltage measurement
Connect the black test lead to the COM jack [4] and the red test lead to the Ω V mA
Set the range selector switch [3] to the desired range in the AC voltage measuring range V
If you do not know the voltage, first set the highest possible measuring range and then reduce it
gradually to the lower ranges until you obtain a satisfactory measurement result.
Connect the test probes [6] to the test object.
The measurement result is then indicated on the display [1].
7.4 AC current measurement
Connect the black test lead to the COM jack [4] and the red test lead to the 10A jack [7] (for
currents > 200mA) or to the Ω V mA
Set the range selector switch [3] to the desired range in the AC current measuring range A
If you do not know the current, first set the highest possible measuring range and then reduce it
gradually to the lower ranges until you obtain a satisfactory measurement result.
Connect the test probes [6] in series to the test object.
The measurement result is then indicated on the display [1].
7.5 DC current measurement
Connect the black test lead to the COM jack [4] and the red test lead to the 10A jack [7] (for
currents > 200mA) or to the Ω V mA
Set the range selector switch [3] to the desired range in the DC current measuring range A
If you do not know the current, first set the highest possible measuring range and then reduce it
gradually to the lower ranges until you obtain a satisfactory measurement result.
Connect the test probes [6] in series to the test object.
The measurement result is then indicated on the display [1]. A negative sign is indicated in front of
the measured value for a negative measurement result.
jack [5] (for currents < 200mA).
jack [5] (for currents < 200mA).
POWERFIX PDM 300 B1
jack [5].
.
~
.
~
.
English - 57