PREPARATIONS FOR USE
Remove the front panel (item 5 illustration 1) by lifting it up-
and-out.
Remove the foot-pedal console (items 6 illustration 1) by lifting
it up and folding it out to the side (see illustration 2).
Solvent drums for the left side of the unit
Two drums are needed, one drum that is
of solvent.
full
Both drums must be of the same size,
must meet the requirements described under chapter PERMIT-
TED SOLVENT DRUMS. Both drums must be clean on the inside
and they must not contain any solids or other objects that
could be sucked into the pumps when running.
Drum plugs
There are several types of solvent drums on the market, each
with different diameter of the opening. With the unit, a card-
board box with a selection of tapered plugs is supplied (see
illustration 3). Select the plug that fi t well into the opening of
the drums, and fi t them onto the drum adaptor of the hoses
(see illustration 4).
Solvent fi ll-up on the left side of the unit
Use one empty drum and another drum of the same size full of
clean solvent.
Place the empty drum to the left underneath the unit (item 2
illustration 2). Insert the group of hoses containing the drain
hose from the sink into this drum (item 4 illustration 2). Make
sure that the hoses are properly led well down into the drum,
and that the opening is well sealed by the tapered plug.
Take the second drum, the one full of solvent, and pour half of
its contents directly into the gun cleaner's sink (item 2 illustra-
tion 1). The solvent that is poured in will drain into the drum
underneath the gun cleaner. Make sure to have the ventilation
running during this procedure.
Place the second drum, now half full, on the fl oor on the right-
hand side of the fi rst drum (item 3 illustration 2). Insert the
second group of hoses containing a white hose into this drum
(item 5 illustration 2). Make sure that the hoses are properly
led into the drum all the way down to the bottom, and that the
opening is well sealed by the tapered plug.
The solvent system is now fi lled-up. Both drums should be half
full. The left-hand drum, contains the solvent that will be recir-
culating for the automatic wash cycle, and the right-hand drum
contains clean solvent for rinsing. The contents of the right
drum will gradually be used up and transferred to the left drum.
Water
Fill the fi ltrate container (item 7 illustration 2) up to 100mm
(4") under the upper edge with clean water.
16016 rev 2014-11-06
Operating instructions
Operating instructions should be formulated on the basis of
this manual and translated into the language spoken by the
employees. It should always be available close to the machine.
To avoid confusion, the employees must be informed about the
solvent currently being used in the machine.
SERVICE
, and one drum
empty
and they
Weekly:
– Remove the strainers at the bottom of the automatic
Monthly:
– Remove the fi ve nozzles in the automatic washer and clean
When changing drums:
– Check and if necessary clean the strainers on the suction
When changing fi lters:
– Check and if necessary clean the strainer on the suction
– Take out the fi ltrate container (item 7 illustration 2) and
Every month:
– Change the water completely.
washer (item 2 illustration 5) and clean it,
re-fi t it !
them with clean solvent. (see illustration 8).
hoses.
pipe(item 15 illustration 2) .
empty it completely. Rinse it with water and wipe it off with
cloth or paper.
do not forget to