Supplied contents
Submersible pump
Operating instructions
Hose connection with pump tube bend
If there are parts missing or they are damaged, please contact the vendor from whom you bought
the machine.

3. PUTTING INTO OPERATION

Installation
Submersible pumps are installed as follows:
in a permanent position with a rigid pipe.
in a permanent position with a fl exible pipe.
You should never install the pump by hanging it on the outlet hose or power cord without
additional support.
The submersible pump must be hung on a holder, or it must be placed on the bottom of the
tank.
For the pump to function correctly the bottom part of the tank must be protected against any
kind of dirt (applies to clean water pumps) and against any larger residue (for the size of dirty
material see the technical specifi cations of the individual models).
If the water level declines too much, any residue in the pumping pit will quickly dry out and
prevent the pump from starting again. It is therefore essential to regularly inspect the
submersible pump (by starting it).
The fl oat is set up in such a way that the pump may be started immediately.
After carefully reading these instructions you can prepare your pump for operation, however, keep
the following points in mind:
Check that the pump is standing on the bottom of the tank.
Check that the outlet hose has been attached correctly.
Check that the electrical connection is 230 V ~ 50 Hz.
Check that the power socket is in good condition.
Ensure that the moisture from the water can never get to the electrical power source.
Prevent the pump from running empty.
Before putting the pump into operation, please check the following points:
The switching fl oat is installed in such a way that it is possible to reach the activation level
or the shut off level with only a small amount of force. After checking this installation, place
the pump into a tank with water and carefully lift the switching fl oat by hand and then put it
down again. During this activity watch that the pump has started and then turned itself off.
SUBMERSIBLE PUMP