Warning
Before Operation
The manual contains vital and essential information. The owner should read and understand this important
document before operating the charger. Contact REYA if you do not understand a statement.
Before Installation
In order to avoid overcharging or irreversible damage to the materials, please follow closely all recommendations
cited below. Do not install this system near inflammable materials. An owner should seek guidance from an
authorized DOLPHIN dealer or the factory.
Do not install this system near a heat source
It should not be installed in an airtight or badly ventilated area.
All ventilation ducts must be unobstructed
Mount in a vertical position, to create natural ventilation for the charger. Note that the wiring connections are
at the bottom of the charger. Leave at least three inches clearance above and below the unit for proper
ventilation.
This system should not be exposed to water or dust.
It is strictly forbidden to tamper with the system casing.
Connecting the Unit
In order to avoid all risk of electric shock or irreversible damage to the unit, please follow very carefully the
following recommendations
This unit is set to be connected to a monophase network 230V 50Hz or 115V 60Hz
On the 12V 10A and 12V 15A models, the 115V/230V selection is done by an internal switch. This
manipulation must be done when the device is switched off. The position of the switch must follow the sector
power supply conditions.
On the 12V 20A, 115V/230V selection is automatic.
For security reasons, the system's PE terminal must strictly be connected to the installation's Earth
(green/yellow wire in the cable section)
To prevent overheating, ensure the correct connection of cables.
NB: If reverse polarity of the batteries occurs, the battery fuses will automatically blow.
Start up precautions
In order to prevent all risk of electric shocks at either start up or during the utilization of this system, the
protection cap must rest in place and be tightly screwed.
Maintenance precautions
In order to prevent risk of electric shocks during maintenance, please follow closely all recommendations below
before any maintenance begins.
Disconnect the cable
The access to -DC or -BAT must be disconnected in order to avoid transfer of energy.
Please wait five minutes before accessing the casing as the high-tension condensation will need time to
discharge.
Fuses must be replaced by fuses that have the same characteristics and performance levels.