Output Distribution
AC Connections
PE Connections
Protection characteristics
Outputs
Outlet connections
PE Connections
Protection characteristics
Box
Mounting
Height x width x depth
Weight
Security
Led OFF
Non-current carrying charger
•
Check the presence of the line voltage
•
Check the adjusting input voltage
•
Check the main fuse
Defective internal temperature (12V 15A & 20A only)
•
Check the installation and climatic conditions
•
Check the internal fan is operational
ON/OFF Led is blinking
Charger incorrectly connected to the battery
•
Check battery connection
Battery fuses blown
•
Check the battery cables polarity
•
Replace the battery fuses with identical fuses
Very flat batteries
•
Charge the battery using an external source
Replace the faulty battery
•
12V 10A
16A, 6.5KA, 30mA, 4 module circuit breaker
Thermo-magnetic circuit breakers
10A, 6.5KA, 1 module circuit breaker
Wall mounted - 4 x 4mm (0.1576") ∅screws
280 x 270 x 100 mm (11.03" x 10.64" x 3.94")
Operating instructions
LED "On/Off"
12V 15A
By differential circuit breaker
M6 bolts on the box
2 protected outputs
M6 bolts on the box
Painted aluminum
3kg (6.62lbs)
ISO13297
12V 20A
4