Descargar Imprimir esta página

Pump Assembly; Electrical System - Thetford SANICON TURBO 600S Manual Del Propietario Y Instalación

Publicidad

Electrical Planning
2A
K4
Ref.
Description
K1
Macerator Pump
K3
Macerator Switch
K4
35A Fuse/Breaker
2A
Battery
2B
Relay
2C
Over-Temperature Switch (90°C) normally closed
2D
Ground
Fig. 2
represents recommended wiring confi guration. Other wir-
ing confi gurations are possible based on your installation.
Wiring confi guration MUST include internal over-tempera-
ture switch and relay for protection of pump.
Pump requires a 12-VDC/35 AMP dedicated circuit with 35
AMP breaker or fuse between main bus or battery.
Wire size is dependent on distance between pump and
power source. Actual wire sizes should be calculated ac-
cording to installation.
Electrical System
Wire Gauge Size Chart
If Wire Gauge for distance from
source* is:
12 VOLTS - Install
* Distance measured assumes power
and ground wires
97573 Rev. E (01/08/18)
Fig. 2
Switch Box Assembly
2B
86
85
0-18 feet
19-32 Feet
(Included)
10 Gauge
8 Gauge
Fig. 3
4
K3
K1
While the pump is turned on, verify electrical system
NOTICE
AVISO
CAUTION
AVIS
!
by measuring voltage at motor; (must be 12V).
Improper installation may cause damage to motor or
decrease pump effi ciency.
The positive and negative wires should be braided to
NOTICE
prevent radio interference during operation.
33-50 feet
6 Gauge

Pump Assembly

2C
18G BLU
18G BLU
2D
Included in product
Circuit Breaker
35 amp
®
SANICON
Turbo - Model 600S

Publicidad

Capítulos

Solución de problemas

loading