Programming the open limit
Press "SET" button for 3 seconds, both "SET" and "OL" lights are switched on. Press "OPEN"
button and hold on, till the door lifts to the needed height, then press "SET" to have the open limit.
At the same time the "OL" light switches off, the "CL" light is on, this means that you can go to the
programming of the limit in closing.
Programming the close limit
Press "CLOSE" button and hold on till the door is completely closed, then press "SET" to save the
limit in closing. At the same time Led 5 "POWER" turns on and the door automatically executes
an opening and reclosing cycle.
Trimmer adjustment
In case of automatic relcosing the TR1 trimmer will set the pausing time from 1 to 100s.
trimmer is turned fully counter-clockwise it will set the semi- automatic logic.
Adjusting the running force
Attention: In normal conditions the running force does not have to be adjusted. It can be modified
when the working conditions of the door have to be changed.
The running force can be set on DIP1, DIP2. There are one to four levels.
67411340
µP
L5
POWER (Alimentazione)
J1
L4
L3
L2
S4
S3
S2
CLOSE
OPEN
SET
RX
ON
1
2
1 Level
2 Level
Minimum force
DIP
1 2
Courtesy
light
TX
PHOTOCELL
FORCE SETTING
ON
ON
1
2
1
2
3 Level
REV 06 - 06/2014
M
24Vac
J4
+MOTOR- TRANSF.
WALL
SWITCH
LEARN
LEARN
CLOSE
LEARN
LEARN
CLOSE
If the
NOTE: You can find the
ON
version with 3 DIPs where
with DIP1 you can choose
between automatic and semi-
automatic logic and with DIP 2
1
2
and DIP3 you can adjust the
4 Level
force level.
Maximum force
English
J5
F1
CL
OL
SET
OPEN
SET
CL
OL
SET
OPEN
SET
13