2VOICE SIDE WIRING INSTRUCTIONS

Cx = distance between gateway and calling station
D
= distance between gateway and 2Voice power unit
Ax = distance between 4-user distributor and apartment station
Bvx = distance between gateway from where the backbone derives and the most distant 4-user distributor

MAXIMUM DISTANCES

Wire
2Voice wire Ref. 1083/92
2Voice wire Ref. 1083/94
(*) The system extension is given by the sum of all its sections: C1+C2+D+Bv1+Bv2+A1+A2+...+An
For more information on wire types and respective distances follow the rules shown in the 2VOICE SYSTEM
manual, section 2.

WIRING INSTRUCTIONS IPERCOM SIDE

Ethernet RJ45 wire
The IperCom system was developed for operating with EIA/TIA 568B standard.
Connect the wire to one of the RJ45 connectors with Urmet logo.
Insert the wire in the guide respecting the color-coding shown (Standard T568B).
Grey sheath
DS1083-113
apartment station
column
2
Bv1
1
D
gateway
2voice
power unit
to the Ipercom
system
Number of
apartment
stations
128
100
Wire
No.
1
2
1
3
4
8
A1
A2
Bv2
calling station
C2
C1
calling station
Distance
Ax
Cx
D
200m
5m
50m
125m
5m
50m
Cable colour
White-Orange
Orange
White-Green
Blue
secondary
TC
TC
secondary
Bvx
Ax+Bvx
200m
200m
125m
125m
Wire
Cable colour
No.
5
White-Blue
6
Green
7
White-Brown
8
Brown
Extension
(*)
800m
800m
11