2. Insert the retainers B of the spacer in the DIN rail in such a way that the terminal strips of the device are
pointing downwards, then insert the retainers C.
3. Remove the terminal strip cover.
4. Connect the assembly to the system.
The end of a stranded conductor must not be consolidated with mild soldering in the points in
which the conductor is subject to contact pressure.
5. Reposition the terminal board cover.
6. Power the device.

CONFIGURATION

For correct confi guration, fi rst confi gure the 2Voice side of the gateway, making reference to the system
manual for video door phone confi guration and the manual provided with the keypad.
Then, confi gure the IperCom side with reference to the Technical Manuals / Communication / IperCom
System section on the www.urmet.com website.
The guaranteed conversation time and reply time must be identical in the IperCom and 2Voice
systems.
The concierge switchboards must necessarily be Ref. 1060/41 devices.

TECHNICAL SPECIFICATIONS

Working temperature range:.......................................................................................................... -5 ÷ +45 °C
Dimensions Ref. 1083/59 on DIN bar (LxHxP): .....................................140 (~8 DIN modules) x 90 x 60 mm
Wires with cross-section area of 0.5 mm
cross section area smaller than 0.5 mm

ADVANCED INFORMATION

For:
operation of the device;
2Voice system regulations and immunity to disturbances;
2Voice system testing.
refer to the 2Voice technical manual in the Technical Manuals / Communication / 2Voice System section
which can be downloaded from the www.urmet.com website (free registration required).