OPERATION
Flow CIRCULATION for the DEHUMIDIFICATION function.
AIRFLOW 1
As shown in the figure below, the air is directed onto the evaporator, which cools
the air flows in the direction of the outlet of the apparatus.
AIRFLOW 2
The air is thus directed onto the condenser which reheats the air. These two sys-
tems of atmospheric current separate the hot air flow from the cool airflow. The hot
air is expelled through the back outlet of the apparatus and the cool air is expelled
from the front of the air conditioner.
Evaporator
Cool air
Upper fan motor
airflow 1
Lower fan motor
Capillaire
Warm air
airflow 2
Compressor
Condenser
Flow CIRCULATION for the DEHUMIDIFICATION function
When you switch on the apparatus, the compressor and the ventilation work, the
refrigerant with a low pressure and a low temperature enters the compressor,
pressurised at high pressure and high temperature, the gas then flowing to the
condenser.