Adjusting The Air Flow Direction; Outdoor Coils - LG W092CA SG1 Manual Del Usuario

Tipo de ventana
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

How to Attach Drain Pan (Some Models)
The air conditioner employs a proper drain method whereby the condensed water (moisture removed from the
air) is drained to the outside.
In very humid weather, (and for reverse cycle models in the reverse mode) excessive condensate water removed
from the air may cause some water to collect. To remove this excess water you can install the drain pan as
detailed below.
1. Take the drain pan which is located in the air discharge.
2. Remove the hole rubber from the base-pan (for some models).
3. Install the drain pan to the right corner of the cabinet with 4 (or 2)
screws.
4. Connect the drain hose to the outlet located at the bottom of the
drain pan.You can purchase the drain hose or tubing locally to
satisfy your particular needs. (Drain hose is not supplied).
How to Connect a Drain Hose
A drain hole is provided at the rear of the air conditioner unit.
Select a drain method according to the following.
1. Remove the hole rubber from the base-pan. (for some models)
2. Connect a drain hose to the drain pipe as shown in Fig. 1.
3. Or connect a pipe elbow to the drain pipe, then connect a drain hose
to the pipe elbow as shown in Fig. 2.
Operating
Instructions
TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked
regularly. If they are clogged with dirt or soot they may be professionally
steam cleaned, a service available through a dealer.

Adjusting the Air Flow Direction

DRAIN
PAN
SCREW
DRAIN HOSE
12
CABINET
Fig. 1
DRAIN PIPE
DRAIN HOSE
Fig. 2
DRAIN PIPE
DRAIN ELBOW
DRAIN HOSE

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

W121ca tsc2W122caW122cmW121cmW121ca

Tabla de contenido