C. Precautions for use
» Do not leave the Blue Connect on the Blue Fit50 when there is no
water in the pipes.
» If handling on the hydraulic circuit (risk of water hammer), it is
advisable to remove the Blue Connect in order not to damage the
product.
» Make sure to create a sufficient flow in your installation so that the
Blue Connect can take measures.
» Always place the Blue Connect vertically with the probe
downwards.
» Blue Fit50 cannot be attached to flexible hoses
» Blue Fit50 withstands a maximum pressure of 3 bar
» Blue Fit50 is used on a 50mm pipe in Europe and a 60mm pipe
for the USA and Australia.
Blue Fit50 installation
Note: Feel free to ask your pool specialist for advice in case of any
doubt.
A. Find the correct location
Make sure to always place the Blue Fit50 after the filter (to avoid
damaging the probes) and before your product injection system
or electrolysis (to avoid altering the measures taken by the Blue
Connect).