2.4.1
Noise emission specifications
Noise emission values determined according to DIN EN ISO 3744:
Sound pressure level
Uncertainty
Sound power level
Uncertainty
The noise measurement was done without tool at idling speed.

2.5 Scope of supply

Operating manual
Open-ended spanner AF 17
Open-ended spanner AF 25
Collet OZ ø / mm
Collet ER 16
Cable / m
Covering cap Z

2.6 Use according to intended purpose

- The power tool is intended for permanent installation in guiding portal systems with ø 43 mm clamping
collar.
- The power tool with quick tool clamping can be flanged directly to a portal system using six screws (M6
thread) according to the specifications of the portal system (Fig. 5).
- The power tool is not designed for continuous industrial operation.
- The power tool is considered an incomplete machine. The power tool must not be put into operation until it
has been established that the portal system in which the power tool is to be installed complies with the
provisions of the current and valid Machinery Directive. Please also observe the corresponding warranty
conditions for the power tool and any additional equipment.

2.7 Residual risks

- Breakage of the rotating tool.
- Breakage of the tools and risk of the tools or parts of them being hurled away.
- Touching live parts with the housing open and the mains plug not removed.
- Hearing can be impaired when working for long periods without ear protectors.
- Emission of hazardous or potentially explosive dusts (all types) during longer lasting operation without
extraction. Please note the safety data sheet of the material to be machined.
x
x
x
x
-
-
6
8
-
-
1
4
-
-
Danger
Even if used in accordance with its intended purpose and despite conforming with the
safety instructions, residual risks caused by the intended use will always remain.
L
= 71 dB (A)
PA
K
= 3 dB (A)
PA
L
= 82 dB (A)
PA
K
= 3 dB (A)
PA