30" GAS SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire
or explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY:
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
These surfaces should be flat
& leveled (hatched area).
1 ½" Max.
(3,8 cm Max.)
Shave
Raised
Edge
to Clear
Space
for a 31½"
(80 cm) Wide
Cooktop.
Locate Cabinet Doors 1" (2,5 cm)
Min. from Cutout Opening.
IMPORTANT:
Cabinet and
countertop width
should match the
cutout width.
A. HEIGHT
B. WIDTH
35 5/8" (90.5 cm)
30" (76,2 cm)
- 36 5/8" (93 cm)
NOTE: Wiring diagram for these appliances are enclosed in this booklet.
Printed in United States
(Models with Sealed Top Burners)
WALL
1/2" min.
5" Min.
(12,7 cm Min.)
From Wall Both Sides
E
E
C. COOKTOP
D. DEPTH TO
WIDTH
FRONT OF RANGE
31½" (80 cm)
28 5/16" (71,9 cm)
30" Min.
(76,2 cm Min.)
30" Min.
(76,2 cm) Min.
(see Note 3)
E
31 1/2"
(81 cm)
Exact
G
F
Grounded Junction Box or Wall Outlet Should Be
Located 8" to 17" (20,3 cm to 43,2 cm) From Right
Cabinet and 2" to 4" (5,1 cm to 10,2 cm) From Floor.
E. CUTOUT WIDTH*
(Countertop and
Cabinet)
30±1/16" (76,2±0,15 cm)
1
Refer to your serial plate for
applicable agency certification
Appliances Installed in the
state of Massachusetts:
This Appliance can only be installed
in the state of Massachusetts by a
Massachusetts licensed plumber or
gasfitter.
This appliance must be installed
with a three (3) foot / 36 in. long
flexible gas connector.
A"T" handle type manual gas
valve must be installed in the gas
supply line to this appliance.
18" Min.
(45,7 cm) Min.
3/8" min.
1/2" min.
Approx. 1 7/8"
(4,8 cm)
24" Min.
(61 cm Min.)
F. CUTOUT
G. HEIGHT
DEPTH
OF COUNTERTOP
21 3/4" (55,2 cm) Min.
36 5/8" (93 cm) Max.
22 1/8" (56,2 cm) Max
35 3/4" (90.8 cm)
24" (61 cm) Min. with
backguard
P/N 318201686 (1010) Rev. B
English – pages 1-12; Español – páginas 13-24;
Français - pages 25-36; Notes - pages 37-38;
Wiring Diagrams - pages 39-40
13"
(33 cm)
Min.