SPECTRE Access UHF
Read only
Installation procedure
SPECTRE Module Access - SMA
Frequency Band: 865 - 868 MHz
Frequency Band: 902 - 928 MHz
Use an AC/DC power supply LPS type, Limited Power Source (as per IEC EN 60950-1 Ed2) or ES1 type, PS1 (as per IEC EN 62368-1) for main supply and for
an eventual V+/V-.
Main power supply:
Range +9 Vdc up to +36 Vdc
Consumption:
Typical: 1A under +12 Vdc
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock & Data)
Pin out:
Removable connectors 3x4 pins and 1x8 pins, thread 3.81 mm / 0.149 in
Temperature:
-25 to +60 °C / -13 to +140 °F
Protection:
IP66 level
Chip:
EPC1 Gen2 (ISO 18000-63) - 1 to 62 bytes max
I/O:
4 optocoupled inputs and 4 optocoupled outputs
Module LED:
1 red LED: presence of power supply and 1 green LED: activity on Reader / host link
Antenna LED:
7 configurable colors (red, green, blue, orange, purple, turquoise, white)
Use a multi-conductor shielded twisted pair cable.
Max length RS485:
3 280.84 ft / 1000 m at 9600 baud.
Max length RS232:
49.21 ft / 15 m.
Wiegand / Clock & Data:
1 pair AWG24 – 30 m / 98.43 ft max
1 pair AWG20 – 50 m / 164.04 ft max
Install the module/reader away from computer transmission cables or from power sources (ex: RJ45, sector...).
The disruptions that they can cause can vary according to their radiation power and their proximity.
Use a filtered and regulated power supply.
Antennas connected to different modules/readers may interfere with each other. Move them away from each other.
A power supply which provides 1.5 A min under +12Vdc is recommended.
If the IN/OUT are powered by the module, use a 2A min under +12Vdc power supply.
Users must not remain within a range of less than, 25 cm / 9.84 in from an antenna for an extended period of time as per EN50364 applicable to this
type of device.
Apart from the hatch the module housings must not be opened.
Before any service operation you must de-energize reader.
Check that the hatch seal is correctly positioned before closing.
Do not remove the caps of unused
cable glands:
In order to access the module/reader connectors, open
the hatch.
Cable glands (Data Bus-Power sup. - Input/Output)
© STid 2018 - 20 PA des Pradeaux FR13850 Gréasque - NI1127X01 - Page 1 sur 15 - Ed. 12/12/2018
UHF SPECTRE Access
Lecture seule
Notice d'installation
SMA-R41-A-U04: TTL
SMA-R42-A-U04: RS232
SMA-R43-A-U04: RS485
SMA-R51-A-U04: TTL
SMA-R52-A-U04: RS232
SMA-R53-A-U04: RS485
Power Supply Characteristics - SMA /SLA
Typical: 12 Vdc
Max: 1.5A under +12 Vdc
Characteristics - SMA / SLA
Recommended Cables - SMA / SLA
2 pairs AWG24 – 60 m / 196.85 ft max
2 pairs AWG20 – 100 m / 328.08 ft max
Recommendations - SMA / SLA
Do not remove the caps from the unused
RF connectors:
Host Connection Access - SMA / SLA
only
the hatch provided for this purpose by unscrewing the 4 captive screws without removing them from
Front View of the Module - SMA / SLA
Green LED
Red LED
Acceso UHF SPECTRE
Solo lectura
Manual de instalación
SPECTRE Reader Access - SLA
Frequency Band: 865 - 868 MHz
Frequency Band: 902 - 928 MHz
3 pairs AWG24 – 100 m / 328.08 ft max
Install the module/reader with the word UP
facing upwards so that the connectors are down:
RF port 2
RF port 3
RF port 1
SLA-R41-A-U04: TTL
SLA-R42-A-U04: RS232
SLA-R43-A-U04: RS485
SLA-R51-A-U04: TTL
SLA-R52-A-U04: RS232
SLA-R53-A-U04: RS485
RF port 4
US
FR
ES