Operation; Cleaning And Maintenance; Troubleshooting - Broan LP80 Guia De Instalacion

Ventilador de bajo perfil
Ocultar thumbs Ver también para LP80:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 7

Operation

To Operate Fan
Use an ON/OFF switch or speed control to operate this
ventilator.
WARNING
Before servicing or cleaning unit,
switch power off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.

Cleaning and Maintenance

To Clean
For quiet and efficient operation, long life and attractive
appearance, remove Grille and vacuum interior of unit with
a dusting brush attachment.
The Motor is permanently lubricated and never needs
oiling. If the motor bearings are making excessive or
unusual noises, replace the Motor.

Troubleshooting

Symptom: The fan does not run.
• Check for an open fuse or circuit breaker in the building's
service panel.
• Check that the plug-in connection for the Motor is seated
firmly in place.
• Check that the Blower Wheel spins freely.
Symptom: The fan runs erratically.
• Check that the Blower Wheel is firmly attached to the
Motor shaft and both spin freely.
Symptom: The fan seems noisy.
• Check that the back draft damper in the fan's Duct
Connector pivots freely. Screws used to attach the
ducting to the Duct Connector may be preventing the
damper from opening.
• Check that the back draft damper in the wall or roof cap
pivots freely. These dampers are sometimes mistakenly
painted shut or obstructed by bird and insect debris.
LP80 & LP110
Installation Guide
n

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Lp110

Tabla de contenido