Broan LOSONE SELECT L900 Serie Manual De Instrucciones
Broan LOSONE SELECT L900 Serie Manual De Instrucciones

Broan LOSONE SELECT L900 Serie Manual De Instrucciones

Ocultar thumbs Ver también para LOSONE SELECT L900 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

LOSONE SELECT
VENTILATORS
Ceiling / Wall Mount
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
®
TABLE OF CONTENTS
This manual is divided into sections as follows:
• "WARRANTY"
• "TYPICAL INSTALLATION"
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (horizontal blower discharge)
• "MOUNTING OPTIONS"
• "WIRING OPTIONS"
-Wiring Plate Position
• "DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (vertical blower discharge)
• "USE AND CARE"
• "SERVICE PARTS"
WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period of one year
from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without
charge, any product or part which is found to be defective under normal use and ser-
vice.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND
TUBES. This warranty does not cover (a) normal maintenance and service or (b) any
products or parts which have been subject to misuse, negligence, accident, improper
maintenance or repair (other than by Broan-NuTone), faulty installation or installation
contrary to recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for
the express warranty. Some states do not allow limitation on how long an implied war-
ranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE-NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLU-
SIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE-NUTONE SHALL NOT
BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARIS-
ING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which
vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone-NuTone at the ad-
dress stated below or telephone: 1-800-637-1453, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or part. At the
time of requesting warranty service, you must present evidence of the original pur-
chase date.
In the U.S., contact: Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027
(1-800-637-1453)
In Canada, contact: Broan-Nutone Canada, Inc., 1140 Tristar Drive Mississauga,
Ontario L5T 1H9 (1-888-882-7626)
LOSONE SELECT
L900 SERIES • L1500 SERIES
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
®
Page 1
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan LOSONE SELECT L900 Serie

  • Página 1 9. Never place a switch where it can be reached from a tub or During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and ser- shower.
  • Página 2: Typical Installation

    LOSONE SELECT ® L900 SERIES • L1500 SERIES Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) WIRING 12” ROUND DUCT BLACK 8” X 12” TO 12” ROUND BLACK EDGE TRANSITION OF HOUSING CEILING GROUND TO JOIST WIRING PLATE (24”...
  • Página 3: Mounting Options

    LOSONE SELECT ® L900 SERIES • L1500 SERIES Page 3 MOUNTING OPTIONS DUCTING OPTIONS ¼-20 hex nuts secure mounting brackets to housing. Loosen and BLOWER DISCHARGE POSITIONS re-tighten or remove and replace nuts as necessary for desired mounting bracket position. DUCT MOVABLE yyy @@ @@ @@ @@ @@ @@ yy...
  • Página 4: Service Parts

    LOSONE SELECT ® L900 SERIES • L1500 SERIES Page 4 SERVICE PARTS SERVICE PARTS KEY NO. PART NO. DESCRIPTION 97014853 Damper Flap 99150415 Screw, #8B x ¼* (10 req.) 98009520 Duct Connector 97014784 Housing Assembly 97014728 Mounting Bracket (2 req.) 99150591 Mounting Screw, #10-12 x .625 (4 req.) 97006142...
  • Página 5: Para Montaje En Cielo Raso / Pared

    GFCI (Cortacicuito Accidental a Tierra). O APTITUD PARA UN PROPOSITO PARTICULAR. Durante este período de un año, Broan reparará o cambiará, a su opción y sin cobro, cualqui- 9. Nunca instale un interruptor donde se pueda alcanzar desde una er producto o pieza que se encuentre defectuosa bajo uso y servicio normal.
  • Página 6: Instalación Típica

    LOSONE SELECT LOSONE SELECT ® ® L900 SERIES • L1500 SERIES SERIE L900 • SERIE L1500 Página Page 6 INSTALACIÓN TÍPICA INSTALACIÓN TÍPICA MONTAJE (Estructura nueva) CONEXIÓN ELÉCTRICA CONDUCTO REDONDA DE 12” (30,5 cm) NEGRO TRANSICIÓN DE 8” X 12” A NEGRO CANTO DE LA 12”...
  • Página 7: Opciones De Montaje

    LOSONE SELECT LOSONE SELECT ® ® L900 SERIES • L1500 SERIES SERIE L900 • SERIE L1500 Página Page 7 OPCIONES DE MONTAJE OPCIONES PARA LA COLOCACIÓN DE CONDUCTOS Las tuercas hexagonales de ¼ x 20 aseguran las abrazaderas de montaje en el alojamiento. Afloje y vuelva a apretar o quite y reem- POSICIONES DE LA DESCARGA DEL VENTILADOR place las tuercas según sea necesario para colocar las abrazaderas de montaje en la posición deseada.
  • Página 8: Piezas De Servicio

    LOSONE SELECT LOSONE SELECT ® ® L900 SERIES • L1500 SERIES SERIE L900 • SERIE L1500 Página Page 8 PIEZAS DE SERVICIO PIEZAS DE SERVICIO CLAVE Nº. PIEZA Nº. DESCRIPCIÓN 97014853 Solapa del regulador 99150415 Tornillo, #8B x ¼* (se req. 10) 98009520 Conjunto del regulador 97014784...
  • Página 9: Tabla De Contenido

    Cette garantie annule toutes les garanties précédentes. 3. Veuillez lire l´étiquette de spécifications sur le produit pour d´autres Pour le service sous garantie, vous devez (a) aviser Broan á l'adresse ci-dessous, renseignements et exigences. (b) donner le numéro du modèle et l’identification de la pièce et (c) décrire la nature de tout défaut dans le produit ou la pièce.
  • Página 10: Installation Typique

    LOSONE SELECT LOSONE SELECT ® ® L900 SERIES • L1500 SERIES SÉRIE L900 • SÉRIE L1500 Page 10 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE (Construction en cours) CÂBLAGE CONDUIT CIRCULAIRE DE 12 po (30,5 cm) NOIR AU NOIR TRANSITION DE 8 x 12 po au BORD 12 po circulaire (20,3 x 30,5 cm au DU BOÎTIER...
  • Página 11: Options De Montage

    LOSONE SELECT LOSONE SELECT ® ® L900 SERIES • L1500 SERIES SÉRIE L900 • SÉRIE L1500 Page 11 OPTIONS D’INSTALLATION DES CONDUITS OPTIONS DE MONTAGE Des écrous à six pans ¼-20 fixent les supports au boîtier. Desserrer POSITIONS DE LA DÉCHARGE DE LA SOUFFLERIE et resserrer ou retirer et replacer les écrous si nécessaire, selon la CONNECTEUR DU PANNEAU...
  • Página 12: Pièces De Rechange

    LOSONE SELECT LOSONE SELECT ® ® L900 SERIES • L1500 SERIES SÉRIE L900 • SÉRIE L1500 Page 12 PIÈCES DE RECHANGE PIÈCES DE RECHANGE LÉGENDE N DE RÉF. DESCRIPTION 97014853 Clapet 99150415 Vis, #8B x ¼* (10 oblig.) 98009520 Registre 97014784 Boîtier 97014728...

Este manual también es adecuado para:

Losone select l1500 serie

Tabla de contenido