W. TROUBLESHOOTING
Problems
The burner will not light
Burner 'pops' or blows
itself out
Sputtering unsteady flames
Large flames on surface
of burner
Flame low on jet
Excessive grease flare-up
Burners light with a match,
but not with the "PIEZO"
igniter
Fire at any connection
Lack of heat
Fire behind control knob
Fire under control panel
Probable causes / remedies
y Lack of gas supply.
y Regulator does not work.
y Hose, valve, Venturi tube (VT) or burner openings are blocked.
y Venturi tube not seated over jet.
y Check gas supply.
y Check hose connections.
y Contact the After Sales Service.
y New bottle may contain air. Continue use and the problem will disappear.
y Contact the After Sales Service.
y Jet nozzle badly connected to Venturi tube. Adjust the Venturi tube.
y The Venturi tube is clogged (e.g.: cobwebs). Clean Venturi tube.
y Contact the After Sales Service.
y The bottle is almost empty. Change bottle and the problem will disappear.
y Contact the After Sales Service.
y Clean the protective plate above the burner.
y Grill temperature too high: Lower flame.
y Clean the grease drip tray.
y Faulty igniter button, wire or electrode. Check igniter cable connections.
y Check condition of electrode and connection wire.
y Contact the After Sales Service.
y Leaking connection.
y Turn off gas supply immediately.
y Contact the After Sales Service.
y Clogged jet or Venturi tube.
y Contact the After Sales Service.
y Defective tap unit.
y Turn off appliance.
y Contact the After Sales Service.
y Turn off appliance.
y Close gas cylinder.
y Contact the After Sales Service.