Cabinet Cutout Instructions
For proper operation of your cooking appliance, the cabinets
must be properly constructed and squared with respect to
the counter top and the cabinet face.
For proper operation of the appliance, the cabinet must be
level and the bottom of the appliance must be supported.
NOTES:
When planning the location, consider curtains or
other combustible materials installed around the appliance
so as not to create a fire hazard.
The minimum horizontal distance(s) from
appliance to adjacent vertical combustible walls extending
above the top panel:
Item
A
7¼ " Min. (184mm Min.)
B
8" Min. (203mm Min.)
NOTE: These distances shall be from the burner center of
the appliance.
WARNING
The minimum vertical distance to combustible material
above the range cooking top is 30" (762mm), provided the
overhead construction does not extend 13" (330 mm) from
the rear wall.
NOTE: If installing a range hood or microwave hood
combination above the cooking surface, follow the
range hood or microwave hood combination installation
instructions for dimensional clearances above the cooktop
surface.
sides and back of
Dimension
Cabinet and counter cutout chart:
A
17¾ " (451mm)
B
20⅛ " (511mm)
C
41⁄16" (103mm)
D
15⁄16" (23mm) max.
E
19⁄16" (40mm) max.
F
45⁄16" (110mm)
G
39⁄16" (90mm)
Cooktop Installation
When the cabinet has been prepared according to the
dimensions given and the gas line is in place.
1. Take your cooktop out of the carton and place on a flat
surface. Remove the packing materials.
2. Hold the baffle and pull upward to release the top glass
cover assembly from the cooktop. (Fig. 1)
Fig. 1
7