Application; Assembly; Placing The Unit; Collecting Tray - DRESTER RDX 9012 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33

APPLICATION

The DRESTER RDX 9012 is the Docking Unit that, when connected to the DRESTER Gun Cleaner and DRESTER 120 Recycler
forms the closed system called the "DRESTER DYNAMIC TRIPLE". This brings safe handling of both clean and contaminated
solvent. The system eliminates heavy lifting and handling of solvent drums. It minimises solvent losses, and speeds up the work.
This manual describes the DRESTER RDX 9012 Docking Unit, how to install it, and how to operate the complete "DRESTER
DYNAMIC TRIPLE" system. The DRESTER Gun Cleaner is described in detail in the manual supplied with the Gun Cleaner.
The DRESTER 120 Recycler is described in detail in manuals no. 11213-1 and 11213-2.

ASSEMBLY

The DRESTER RDX 9012 Docking Unit is supplied complete in a box. The unit does not require any further assembly. The
Docking Unit is installed in accordance with the instructions below with the aid of the enclosed accessories.
Note: Air lines for compressed air and associated couplings (for 1/4" internal thread) must be supplied by the purchaser.

PLACING THE UNIT

The DRESTER RDX 9012 is placed inside the DRESTER Gun Cleaner. The DRESTER Gun Cleaner with RDX 9012 are
equipment Category 2 (ref. ATEX-directive 94/9 EC) and may therefore be placed in locations classified as Zone 1 (ref. ATEX-
directive 1999/92 EC). If the DRESTER Gun Cleaner with RDX 9012 are installed in locations classified as Zone 2 (or in
unclassified locations), the following is valid provided that the ventilation of the unit is installed as described in the manual
supplied with the Gun Cleaner:
The area inside the unit and inside the ventilation ducting, as well as an area extending 0,5m over and on each side of the unit, as
well as 1m forward from the front of the unit is to be classified as Zone 1.
Furthermore an area extending 0,5 meter outside the described Zone 1, is to be classified as Zone 2.
Within these areas, all equipment such as electrical items must be approved for the Zones described. Equipment that generates
naked flames or sparks (e.g. welding or grinding equipment) may not be used in this area. Smoking is not permitted.
If in any doubt, contact the local fire service authorities for advice.
Always ensure that the unit is correctly grounded.
This manual is part of the equipment and must be kept accessible at all times.

COLLECTING TRAY

To prevent accidental leakage of solvent that runs onto the floor from spreading into a drain water system, the DRESTER Gun
Cleaner with RDX 9012 must be installed in a location where floor and walls can hold the accidental leakage. If this is not
possible, the unit must be equipped with the "DRESTER COLLECTING TRAY 10250".

PREPARATIONS BEFORE INSTALLATION

General
To ensure an effective, trouble-free installation of the DRESTER DYNAMIC TRIPLE, the following preparations should be
made:
DRESTER Gun Cleaner
Install the Gun Cleaner according to the manual supplied with the Gun Cleaner.
DRESTER 120 Recycler
Install the Recycler according to manuals no. 11213-1 and 11213-2. Note that the electrical installation must be carried out by a
qualified electrician.
Compressed air connection
By the Recycler, compressed air of 3–10 bar must be available.
By the Gun Cleaner, compressed air of 7–12 bar must be available.
If the supply of compressed air is between 7 and 10 bar, the system may be connected to the same outlet.
The compressed air supplied to the units must be clean and dry, otherwise it may cause damage to the pneumatic components of
the unit, which will invalidate any warranty claims.
Combined or separate
If the Recycler is to be installed at some distance from the Gun Cleaner, the "PIPING KIT 10810" will be required for installation.
Apart from components, this kit also includes manual no. 11161, which describes such an installation.
Air lines and couplings
Note: Air lines for compressed air and associated couplings (for 1/4" internal thread) must be supplied by the purchaser.
Solvents
60 litres of solvent are required to prime the "DRESTER DYNAMIC TRIPLE" system.
INSTR: 11143
REV: 2 / 14-02-21 / TB
GODK:
SID: 3 / 46

Publicidad

Tabla de contenido
loading

Tabla de contenido