What To Do When You Run Out Of Solvent; Recycling Foreign Solvent - DRESTER RDX 9012 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33

What to do when you run out of solvent:

NO CLEAN SOLVENT IN GUN CLEANER
Do not top up with clean solvent, instead make a transferpumping and start the Recycler.
(See "Operating instructions for the Drester Dynamic Triple" above.)
NO RECIRCULATING SOLVENT IN GUN CLEANER
If the pump for the automatic cleaning cycle only pumps air and no solvent, there is not enough solvent in the Docking Unit. If
this is the case, pour 10 litres of solvent straight into the Gun Cleaner. Check that the level indicator can move freely and that it
sits at a height of 10–70mm. (See Picture below left)

Recycling foreign solvent:

To recycle solvents that are not part of the system, follow the steps listed below:
1. Change the plastic bag in the Recycler
2. Move the distillate container to the side.
3. Place an empty drum that will hold at least 12 litres underneath the Recycler (see Picture below).
4. Fill the Recycler with dirty solvent (no more than 12 litres).
5. Close the lid of the Recycler and start the timer. Note: Information about settings for time and temperature can be found
in the manual for the Recycler, no. 11213, section 5.5.
When the distillation cycle is complete, put the distillate container back in place.
INSTR: 11143
REV: 2 / 14-02-21 / TB
GODK:
SID: 6 / 46

Publicidad

Tabla de contenido
loading

Tabla de contenido