Switching Off The Beep; Display Notices - Stabila LD 400 Información

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Timer (self-triggering)
1x long: The
symbol is displayed.
The timer is preset to 5 seconds.
The value is increased.
Holding the buttons down increases the rate of
change of the values.
The countdown starts automatically (if the laser is
activated) and then triggers the measurement.

Switching off the beep

Press and hold simultaneously for
5 seconds:
The beep is switched off.
To reactivate it, press and hold for 5 seconds.
Stabila LD 400
Appendix

Display Notices

All display notices are either displayed with
"Error". The following errors can be corrected.
Cause
204
Calculation error
252
Temperature too
high
253
Temperature too
low
255
Received signal too
weak, time for a
measurement too
long.
256
Received signal too
strong
257
Faulty measure-
ment, too much
background light
258
Outside of the range
of measurement
Error
Cause
Error
Hardware error
9
or
Correction
Repeat procedure
Let device cool down.
Warm device up
Use a target plate
Use target plate (gray
side)
Use target plate (brown
side)
Select measurement
distance within the
range of measurement
Correction
Should this message
remain active after
switching the instru-
ment off and on several
times, please contact
the dealerhip.