FAULT RECOVERY
Fault Recovery
Fault
The machine does not
work or the indicator
light of switch is not
lighted
The indicator light is on
but there is no steam
The accessories of
ironing brush are not
fastened
Less, discontinuous or
no steam
Less volume of steam
Water don't flow into
boiler
Water tank deformation
Overflow of water tank
If the problems above are still not solved, inform the professionals and do not dismantle the machine
without authorization.
Cause
Power-off or fusion of fuse
The socket is not connected or
plugged in properly
Unfavorable connection of
socket
The power switch is not turned
on
The water in water tank does not
reach the designed water level
The water tank is not installed in
position
Severe inflection of steam
conduit
Water don't flow into boiler
Unaligned grip
The water in water tank does not
reach the designed water level
The water tank is not installed in
position
Severe inflection of steam
conduit
Blockage of filter sieve
Blockage of water tank
Blockage of water intake
The water tank is not installed in
position
Used hot water
Cracking of water tank
Breakage of seal ring
Solution
Check and confirm
Connect to the power supply and ensure the plug is
plugged in thoroughly
Check whether the power socket is normal or not
Turn on the power switch
Fill water promptly
Install the water tank in position
Straighten the steam conduit
Shaking water tank or re-placed the water tank
Realign and fasten the snap close
Fill water promptly
Install the water tank in position
Straighten the steam conduit
Wash the clearing plug at bottom
Wash the filter sieve of water tank
Wash the water intake
Install the water tank in position
Replace the water tank
Replace the water tank
Replace relevant fittings