Description
14 EN
Under Backwash settings, the status,
interval, duration and speed can be
controlled. Under status, "On" (√) and
"Off" can be selected. 7 days is the
default setting for the backwash interval.
The duration of the backwash cycle in
shown in minutes (6 hours – 31 days).
The pump's speed is controlled in levels
with 3 levels to choose from.
(These displays apply for the operation
mode: Interval-automatic)
Under Rinse settings, the duration and
pump speed can be set. The duration is
specified in seconds and the speed is
controlled in levels with 3 levels to choose
from. A duration between 5 and 360
seconds can be selected.