Input For Temperature Sensor - BADU OmniTronic Traducción De Las Instrucciones Para El Manejo Originales

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 254
Input no. 2: Switch on filter pump (in lowered position filter)
DC1 and DC2 potential-free contacts only:
DC1: for potential-free contacts, for example pressure switches
Function: When the pressure switch (t>3s) is triggered, a
backwash/rinse cycle is started (available optionally; article no.
260.6402.087)
DC2: for potential-free contacts, for example manual, external
switches
Function: The pump switches to the "Filter" position as soon as
the switch is closed.
AC1, AC2, N 230 V leading signals only:
AC1: 230 V input, for example remote switches (start backwash
via remote switch)
Function: With a voltage of 230 V (t>3s), a backwash/rinse cycle
is started.
AC2: 230 V input, for example from an external filter control
Function: With a voltage of 230 V and when in the "Filter"
position, the pump switches on.
3.5.8

Input for temperature sensor

DC4: Input for BADU OmniTronic water sensor
DC5: Input for BADU OmniTronic solar sensor
The sensors are available with different cable lengths 5 m and 15
m (optional: 260602117/2606402118).
The temperature sensors are always delivered with a PVC
adhesive flange drilling template. This enables uncomplicated
mounting of the pool water sensor. You can stick it directly onto
Ø50 or Ø63 pipes with this receptacle.
The module can also be used as a solar sensor either for
installation in the pipeline for the solar absorber or for fixing to the
roof.
The sensors are special sensors. Other types cannot be used.
Electrical connection:
[2] / brown wire: DC4 or DC5
[1] / white wire: GND