3.2.1

Basic programme selection

It is possible to choose from two different programmes:
Interval-controlled – notification in display I
Time-controlled – notification in display T
Interval-controlled
Interval control is the simplest method of telling the device which
function it should carry out. It is not necessary to specify a time for
the start of the backwash/rinse cycle or the filter time. The right
hand button on the housing must be pressed for 3 seconds. The
starting time for the backwash cycle and the filter time is then set
permanently. According to the factory settings, the filter duration is
set to 8 hours per day. The repetition cycle (in days) for the
backwash/rinse cycles can be chosen individually. The default
setting is 7 days.
Time-controlled
Exact time specifications are required for the time-controlled
programme. A starting time must be specified for the
backwash/rinse cycles and for the daily filter times. In time mode,
five filter cycles can be set per day. Set the various times and
press the "OK" key ( ) when the enter symbol is displayed. Then
a new cycle will be opened. The device takes daylight saving time
changes into account automatically.
I: Display of the current operating mode:
I: Interval automatic
T: Time controlled automatic
Display of the optimal level switch status:
√ Refill
Display control selection:
Z: Release z1-z2
• : Heating
'': Cooling
☼: Solar
18 EN
Water level in pool ok
Water level too low
04|2019