Before installation, make sure the maximum permissible length has not been exceeded
by means of a simple calculation:
1.
Establish the layout of the system of split flues, including accessories and outlet ter-
minals.
2.
Consult table 6 and identify the losses in m
according to the installation position.
3.
Check that the sum total of losses is less than or equal to the maximum permissible
length in table 5.
Table. 5- Baffles for separate ducts
Max. permissible length
60 m
eq
Baffle to use
0 ÷ 20 m
30 ÷ 45 m
45 ÷ 60 m
For particular installations, with the presence of additional draft or resistance, it
may be necessary to choose a larger or smaller baffle size.
Table. 6 - Accessories
PIPE 1 m M/F
BEND 45° M/F
PIPE SECTION with test point
Ø 80
TERMINAL air, wall
fumes, wall with antiwind
FLUE Split air/fumes 80/80
Fume outlet only Ø80
PIPE 1 m M/F
BEND 90° M/F
Ø 60
REDUCTION 80/60
TERMINAL fumes, wall with antiwind
ATTENTION: CONSIDER THE HIGH PRESSURE LOSSES OF Ø60 ACCESSORIES;
USE THEM ONLY IF NECESSARY AND AT THE LAST FUME EXHAUST SECTION.
Connection to collective flues
C
8X
C
93
fig. 19 - Examples of connection to collective flues (
44
EN
DIVACONDENS D PLUS F 24
(equivalent m) of every component,
eq
Separate ducts
Natural gas
LPG
Ø 43
eq
eq
Ø 45
20 ÷ 30 m
eq
eq
Ø 50
eq
No baffle
45 ÷ 60 m
eq
eq
Losses in m
Air
Fume exhaust
inlet
Vertical
1.0
1.6
1.2
1,5
0.3
2.0
1KWMA86A
-
010027X0
-
010026X0 +
-
1KWMA86U
C
4X
C
2X
C
93
= Air /
cod. 3541P653 - Rev. 01 - 03/2021
Table. 7 - Typology
Type
Description
C2X
Intake and exhaust in common flue (intake and exhaust in same flue)
C4X
Intake and exhaust in common and separate flues, but undergoing similar wind conditions
C8X
Exhaust in single or common flue and wall intake
B3X
Intake from installation room by means of concentric duct (that encloses the exhaust) and exhaust in
common flue with natural draught
IMPORTANT- THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION
C93
Exhaust to a vertical terminal and intake from existing flue.
If the boiler is to be connected DIVACONDENS D PLUS F 24 to a collective flue or to a
single flue with natural draught, the flue or chimney must be expressly designed by pro-
fessionally qualified technical personnel in conformity with the current regulations and be
Ø 43
suitable for sealed chamber units equipped with fan.

4. SERVICE AND MAINTENANCE

Ø 45
Important
Ø 50
All adjustment, conversion, commission-
B
No baffle
ing and maintenance operations described
below must only be carried out by Quali-
fied Personnel (meeting the professional
technical requirements of current regula-
tions) such as the personnel of the Local
eq
After-Sales Technical Service.
Horizontal
FERROLI declines any liability for damage
2.0
and/or injury caused by unqualified and
1.8
unauthorized persons tampering with the
2.0
0.3
unit.
-
4.1 Adjustments
5.0
Gas conversion
12.0
ALL COMPONENTS DAMAGED DURING
4.0
B
CONVERSION OPERATIONS MUST BE
6.0
REPLACED.
4.5
5.0
The unit can operate on natural gas or LPG and is factory-set for use with one of these
7.0
two gases, as clearly shown on the packing and on the data plate. Whenever a gas dif-
ferent from that for which the unit is arranged has to be used, the special conversion kit
will be required, proceeding as follows:
1.
Disconnect the boiler power supply and close the gas cock.
2.
Replace the nozzles at the main burner, fitting the nozzles specified in the technical
data table in cap. 5, according to the type of gas used
3.
Switch the boiler power on and open the gas cock.
4.
Modify the parameter for the type of gas:
put the boiler in standby mode
press the DHW buttons details 1 and 2 - fig. 1 for 10 seconds: the display shows
"b01" flashing.
press the DHW buttons details 1 and 2 - fig. 1 to set the parameter 00 (for nat-
ural gas operation) or 01 (for LPG operation).
press the DHW buttons details 1 and 2 - fig. 1 for 10 seconds.
the boiler will return to standby mode
5.
Adjust the minimum and maximum pressures at the burner (ref. relevant para-
graph), setting the values given in the technical data table for the type of gas used
6.
Apply the sticker contained in the conversion kit, near the data plate as proof of the
conversion.
Activation of Auto-setting function for gas valve calibration
THIS PROCEDURE MUST ONLY BE CARRIED OUT IN THE FOLLOWING CASES:
GAS VALVE REPLACEMENT, CARD REPLACEMENT, CONVERSION FOR GAS
CHANGE.
The B&P Gas Valve (with integrated modulating operator) does not provide for mechan-
ical calibration: the minimum and maximum power adjustments are therefore electroni-
cally done via two parameters:
Contents
Description
q01
Absolute minimum current offset
q02
Absolute maximum current offset
= Fumes)
0÷150