General Troubleshooting Guide
Symptom
Tool runs slowly
or will not operate
Moisture blowing
out of tool
6
Possible Cause(s)
1. Grit or gum in tool
2. No oil in tool
3. Low air pressure
4. Air hose leaks
5. Pressure drops
6. Regulator adjusted
wrong
7. worn ball bearing in
motor or in bearing
housing
8. worn/broken gears
1. water in tank
2. water in the air
lines/hoses
www.campbellhausfeld.com
Corrective Action
1. Flush the tool with Campbell Hausfeld air
tool oil, gum solvent, or an equal mixture of
SAE 10 motor oil and kerosene. If Campbell
Hausfeld oil is not used, lubricate the tool
after cleaning
2. Lubricate the tool according to the lubrication
instructions in this manual
3. Adjust the compressor regulator to tool
maximum while the tool is running free
4. Tighten and seal hose fittings if leaks are
found
5. Be sure hose is properly sized. Long hoses
or tools using large volumes of air may
require a hose with an I.D. of 1/2 inch or
larger depending on total hose length
6. Adjust regulator with a flathead screwdriver
to maximum speed
7. Remove and inspect bearing for rust, dirt, grit
or worn race. Replace bearing
8. Replace gears
1. Drain tank (See air compressor manual). Oil
tool and run until no water is evident. Oil tool
again and run 1-2 seconds
2. a. Install a water separator/filter (PA2100
or PA2110). NOTE: Separators work
properly only when air steam is cool
Locate separator/filter as far as possible
from compressor
2. b. Install an air dryer (PA2085)
2. c. Anytime water enters the tool, the tool
should be oiled immediately