Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

ULTRA SILENT
VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes
and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further
information and requirements.
To register this product visit:
www.broan.com
Installer: Leave this manual with the homeowner.
TM
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive
appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the motor with the exact service motor. The impeller should also
be replaced.
OPERATION
Use an on/off switch or speed control to operate this ventilator.
See "Connect Wiring" for details. Use of speed controls other than
the Broan Models 78V and 78W may cause a motor humming noise.
WARRANTY
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for a period
of three years from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or replace,
without charge, any product or part which is found to be defective under normal
use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS,
TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS,
ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING.
This warranty does not cover (a) normal maintenance and service or (b) any
products or parts which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by Broan-NuTone), faulty installation
or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the three-year period as specified
for the express warranty. Some states do not allow limitation on how long an
implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE
FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING
OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights,
which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or
telephone number below, (b) give the model number and part identification and (c)
describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.broan.com 800-558-1711
Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9
www.broan.ca 877-896-1119
MODEL QTRE080R
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan ULTRA SILENT QTRE080R

  • Página 1 This warranty supersedes all prior warranties. information and requirements. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.
  • Página 2: Typical Installations

    MODEL QTRE080R Page 2 TYPICAL INSTALLATIONS PLAN THE INSTALLATION A mounting frame is provided to allow for accurate positioning of the fan anywhere in the room. It can be COOKING AREA Do not install above or used with I-joists, standard joists and trusses, from 16” inside this area.
  • Página 3: New Construction Installation

    MODEL QTRE080R Page 3 NEW CONSTRUCTION INSTALLATION INSTALL MOUNTING FRAME INSTALL DUCTWORK & HOUSING 4. Connect 4” round ductwork to duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork connections. MOUNTING FRAME TABS SCREW FRAMING OR NAIL (4) MEMBER INSTALL ELECTRICAL WIRING...
  • Página 4 MODEL QTRE080R Page 4 INSTALL THUMBSCREW & GRILLE 6. Install thumbscrew through flange of motor plate THUMBSCREW as shown. 7. Install ceiling material. Cut out around housing. 8. Squeeze grille springs and insert them into slots on each side of housing. Push grille against ceiling. EXISTING CONSTRUCTION INSTALLATION INSTALL MOUNTING FRAME REMOVE EXISTING FAN...
  • Página 5 MODEL QTRE080R Page 5 INSTALL HOUSING EXISTING ELECTRICAL WIRING HOUSING WIRING PLATE (shown MOUNTING removed FRAME from fan housing) DUCT CONNECTOR SCREW BRACKET (provided) SCREW (5) 5. Attach the duct connector bracket to the mounting (provided) frame using the (1) screw provided. Position the bottom edge of the duct connector bracket so it touches the Position the two movable brackets of the mounting finished surface of the ceiling and tighten the screw.
  • Página 6: Service Parts

    Push up near motor plate tab while pushing out on side of housing. Or insert a straight- blade screwdriver into slot in housing (next to tab) and twist screwdriver. Replacement parts can be ordered on our website. Please visit us at www.broan.com 99044515D...
  • Página 7: Nettoyage Et Entretien

    Pour le service sous garantie, vous devez (a) aviser Broan-NuTone à l’adresse ou numéro de téléphone mentionnée ci-dessous, (b) donner le numéro de modèle et l’identification de la pièce et (c) décrire la nature de tout défaut dans le produit ou la pièce. Au moment de la demande de service sous garantie, vous devez présenter une preuve de la date d’achat...
  • Página 8: Planification De L'installation

    MODÈLE QTRE080R Page 8 INSTALLATIONS TYPE PLANIFICATION DE L’INSTALLATION Nous fournissons un cadre de montage permettant de positionner le ventilateur avec précision partout dans la pièce. Vous pouvez l’utiliser avec des solives en I, des solives ordinaires et des fermes de toit espacées de 40,6 à 61 cm ZONE DE CUISSON Ne pas installer au-dessus (16 à...
  • Página 9: Installation Dans Une Construction Neuve

    MODÈLE QTRE080R Page 9 INSTALLATION DANS UNE CONSTRUCTION NEUVE INSTALLATION DU CADRE POSE DES CONDUITS DE MONTAGE ET DU BOÎTIER 4. Connectez un conduit rond de 10,2 cm (4 po) au raccord de conduit. Acheminez le conduit jusqu’au capuchon mural ou de toit. Scellez tous les joints au CADRE DE ruban à...
  • Página 10 MODÈLE QTRE080R Page 10 INSTALLATION DE LA VIS À OREILLES ET DE LA GRILLE 6. Installez la vis à oreilles dans le rebord de la plaque du moteur, tel qu’illustré. VIS À OREILLES 7. Installez le matériau du plafond. Coupez-le autour du boîtier. 8.
  • Página 11: Installation Du Boîtier

    MODÈLE QTRE080R Page 11 INSTALLATION DU BOÎTIER CÂBLAGE ÉLECTRIQUE ACTUEL BOÎTIER PLAQUE CÂBLAGE CADRE DE (illustrée MONTAGE enlevée du boîtier) BRIDE DE RACCORD DE CONDUIT (fournie) VIS (5) 5. Fixez la bride de raccord de conduit au cadre de (fournies) montage à...
  • Página 12: Pièces De Rechange

    Ou encore, insérez la lame d’un tournevis plat dans la fente du boîtier (à côté de l’ergot) et tournez le tournevis. Les pièces de rechange peuvent être commandées sur notre site Web. Visitez notre site à www.broan.com 99044515D...
  • Página 13 Para calificar en la garantía de servicio, usted debe (a) notificar a Broan-NuTone al domicilio o al número de teléfono que se menciona abajo, (b) dar el número del modelo y la identificación de la pieza, y (c) describir la naturaleza de cualquier defecto en el producto o pieza. En el momento de solicitar servicio cubierto por la garantía, usted debe de presentar evidencia de la...
  • Página 14: Instalaciones Típicas

    MODELO QTRE080R Página 14 INSTALACIONES TÍPICAS PLANEACIÓN DE LA INSTALACIÓN Se incluye un soporte de montaje para permitir la colocación precisa del ventilador en cualquier parte de la habitación. Puede usarse con viguetas “I” , viguetas ÁREA PARA COCINAR y vigas estándar, de 40.6 a 61 cm (16 a 24 pulg.) de No instale el equipo sobre centro a centro.
  • Página 15: Instalación En Una Construcción Nueva

    MODELO QTRE080R Página 15 INSTALACIÓN EN UNA CONSTRUCCIÓN NUEVA INSTALE EL MARCO DE INSTALE EL SISTEMA DE MONTAJE Y LA CUBIERTA CONDUCTOS 4. Conecte el conducto redondo de 10.2 cm (4 pulg.) al MARCO conector del conducto. Extienda el conducto hacia DE MONTAJE LENGÜETAS una tapa de techo o tapa de pared.
  • Página 16: Instalación Existente En La Construcción

    MODELO QTRE080R Página 16 INSTALE EL TORNILLO DE APRIETE MANUAL Y LA REJILLA 6. Instale el tornillo de apriete manual a través de la brida de la placa del motor, tal como se ilustra. TORNILLO DE APRIETE MANUAL 7. Instale el material del techo. Recorte alrededor de la cubierta. 8.
  • Página 17: Instale La Cubierta

    MODELO QTRE080R Página 17 INSTALE LA CUBIERTA CABLEADO ELÉCTRICO EXISTENTE CUBIERTA PLACA DE CABLEADO MARCO DE (se muestra MONTAJE quitando la cubierta del SOPORTE DEL ventilador) TORNILLO CONECTOR DEL (incluido) CONDUCTO TORNILLO (5) Fije el soporte del conector del conducto al marco de (incluidos) montaje con el tornillo (1) incluido.
  • Página 18: Piezas De Servicio

    O bien, introduzca un desarmador de punta plana en la ranura de la cubierta (junto a la lengüeta) y dele vuelta. Se pueden hacer los pedidos de las piezas de repuesto en nuestro sitio Web. Visítenos en www.broan.com 99044515D...
  • Página 19 MODEL / MODÈLE / MODELO QTRE080R Page / Página 19...
  • Página 20 MODEL / MODÈLE / MODELO QTRE080R Page / Página 20 99044515D...