Broan QTRE Serie Manual De Instrucciones
Ocultar thumbs Ver también para QTRE Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

QTRE SERIES
FAN / LIGHT / NIGHT LIGHTS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with
the homeowner.
MODELS QTRE080FLT • QTRE110FLT
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
The fan, light, and night light can be operated separately. Use a
3-function wall control. Do not use a dimmer switch to operate
the light. See "Connect Wiring" for details. Use of speed controls
other than the Broan Models 78V and 78W may cause a motor
humming noise.
WARRANTY
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products
that such products will be free from defects in materials or workmanship
for a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or
replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES,
FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSO-
RIES FOR DUCTING. This warranty does not cover (a) normal maintenance
and service or (b) any products or parts which have been subject to mis-
use, negligence, accident, improper maintenance or repair (other than by
Broan-NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EX-
CLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL
NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT
USE OR PERFORMANCE. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation
may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the
address or telephone number stated below, (b) give the model number and
part identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.broan.com 800-558-1711
Register your product online at: www.broan.com/register
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan QTRE Serie

  • Página 1 NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR ties. FITNESS FOR A PARTICULAR PURPOSE. 5. When cutting or drilling into wall or ceiling, do not damage During this three-year period, Broan-NuTone will, at its option, repair or electrical wiring and other hidden utilities. replace, without charge, any product or part which is found to be defective under normal use and service. 6. Ducted fans must always be vented to the outdoors. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP 7. Acceptable for use over a tub or shower when connected to...
  • Página 2: Typical Installations

    MODELS QTRE080FLT • QTRE110FLT Page 2 TYPICAL INSTALLATIONS INSULATION (Can be placed ROOF around and over fan housing.) Housing mounted to I-joists. Housing mounted anywhere be- tween I-joists using hanger bars. HOUSING 4-IN. ROUND DUCT WALL Purchase 4-IN. ROUND separately ELBOW(S) The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number...
  • Página 3 MODELS QTRE080FLT • QTRE110FLT Page 3 1b. Mount housing anywhere between 2. Attach trusses, joists, or I-joists using hanger damper/duct bars. connector. Sliding hanger bars are provided to allow for accurate posi- Snap damper / tioning of housing anywhere between framing. They can be duct connector used on all types of framing (I-joist, standard joist, and truss onto housing. construction) and span up to 24” . Make sure con- nector is flush with top of housing and damper flap falls SCREWS (4) closed. 3. Install 4-inch round ductwork.
  • Página 4: Service Parts

    MODELS QTRE080FLT • QTRE110FLT Page 4 INSTALL GRILLE SERVICE PARTS 5. Finish ceiling. Replacement parts can be ordered on our Install ceiling material. Cut out around housing. website. Please visit us at www.broan.com 6. Attach grille to housing. Squeeze grille springs and insert them into tabs on each side of housing. SERVICE NOTE 7.
  • Página 5: Ventilador/Lámpara/Lámparas De Noche Serie Qtre

    Para tener derecho al servicio de la garantía, usted debe (a) notificar a rociados de yeso, polvos de construcción, etc. Broan-NuTone a la dirección y número de teléfono que aparecen abajo, 4. Léase la etiqueta de especificaciones que tiene el producto para ver (b) proporcionar el número de modelo y la identificación de la pieza y (c) describir la naturaleza de cualquier defecto en el producto o pieza.
  • Página 6: Instalaciones Típicas

    MODELOS QTRE080FLT • QTRE110FLT Página 6 INSTALACIONES TÍPICAS AISLAMIENTO (Puede ser colocado alrededor y sobre TAPA DE de la cubierta del TECHO * ventilador.) Montaje de la cubierta en Montaje de la cubierta en cualqui- CUBIERTA DE viguetas “I”. er parte entre las viguetas “I” por VENTILADOR medio de barras de suspensión.
  • Página 7: Conexión Eléctrica

    MODELOS QTRE080FLT • QTRE110FLT Página 7 1b. Instale la cubierta en cualquier parte 2. Acople el entre las armaduras, viguetas o viguetas conector del “I” por medio de barras de suspensión. regulador de tiro/conducto. Se proporcionan barras de suspensión deslizantes para facilitar la colocación adecuada de la cubierta en cualquier parte entre la Conecte a presión el estructura. Estas barras se adaptan a toda clase de estructuras conector del regulador (construcciones de viguetas “I” , viguetas estándar y armaduras) de tiro/conducto en la y se extienden a un máximo de 61 cm (24 pulg.).
  • Página 8: Piezas De Repuesto

    INSTALE LA REJILLA PIEZAS DE REPUESTO 5. Termine el cielo raso. Las piezas de recambio se pueden ahora pedir en nuestro Instale el material del cielo raso. Recorte alrededor de Web site. Visítenos por favor la cubierta. en www.broan.com 6. Acople la rejilla a la cubierta. Apriete los resortes de la rejilla e insértelos en las lengüetas que...