2. Installation instructions

ATTENTION!
The installation, electrical connection and first operation of this appliance should be carried out by a
qualified installer.
The company does not accept liability for failure of any goods supplied which have not been installed
and operated in accordance with the manufacturer's instructions.
This convector heater must be installed by an authorised serviceman in conjunction with these instructions.
These installation instructions belong to the heater and must be handed on to the successor if the heater is
sold.
AEG convector heaters are direct electric heaters designed to be mounted on the wall and are particularly
suitable for heating smaller rooms such as utility rooms, kitchen, bath- and washrooms etc.
The convector heater is supplied with a lead.
(Exception: WKL502 C to WKL3002 C)
The convector heater must not be mounted immediately
below a wall socket.
During the just operation, the heater may give off a smell.
Ensure that the room is ventilated (for example, open a
window).

2.1 Attaching the wall mounting bracket

The wall mounting bracket is oriented centrally
(see figure and the following table).
Use the wall-mounting bracket as a template for positioning the heater correctly and providing the correct
distance from the floor.
Place the bracket on the floor. Mark the screw-holes through the drill holes ( ).
Type
Connecting power
Breadth
Heigth
Depth
with wall mounting
Measure A
Weight
Raise the bracket and position it in such a way that holes B
are aligned with the marks on the wall you have just made.
Now mark the upper holes through holes C and D in the wall
mounting ( II ).
Drill the four holes, insert plugs and screw the wall mounting
securely to the wall using four screws.

2.2 Wall mounting the convector

On the backside of the convector there are 4 slots, these
should be hooked onto the wall bracket and pushed down.
The spring clips should be turned clockwise to secure.
To remove the convector reverse the above operation.
WKL
WKL
502
752
W
500
750
mm
370
370
mm
450
450
mm
78
78
100
100
121
121
kg
4.1
4.1
For the Professional
WKL
WKL
WKL
1002
1502
2002
1000
1500
2000
445
590
740
450
450
450
78
78
78
100
100
100
195
343
491
4.7
6.1
7.4
WKL
WKL
2502
3002
2500
3000
890
1036
450
450
78
78
100
100
639
790
8.1
10.0
7