ROUTER
DW614, DW615
Congratulations!
You have chosen a D
WALT tool. Years of
E
experience, thorough product development and
innovation make D
WALT one of the most reliable
E
partners for professional power tool users.
Technical data
DW614
Voltage
V
UK & Ireland
V
230/115
Type
Power input
W
Power output
W
No-load speed
min
-1
24,000
Router carriage
2 columns
Plunge
mm
Revolver depth stop
kg
3-step,
graduation
Collet size
(GB: 1/4")
Cutters diameter, max.
mm
Weight
kg
L
(sound pressure)
dB(A)
PA
K
(sound pressure
PA
uncertainty)
dB(A)
L
(sound power)
dB(A)
WA
K
(sound power
WA
uncertainty)
dB(A)
Vibration total values (triax vector sum) determined
according to EN 60745:
Vibration emission value a
h
a
=
m/s²
h
Uncertainty K =
m/s²
The vibration emission level given in this information
sheet has been measured in accordance with a
standardised test given in EN 60745 and may be
used to compare one tool with another. It may be
used for a preliminary assessment of exposure.
DW615
230
230
230/115
4
4/5
750
900
500
590
8,000-24,000
2 columns
35
35
3-step,
with
with
graduation
8 mm
8 mm
Fuses:
(GB: 1/4")
Europe
30
30
U.K. & Ireland
2.8
2.9
U.K. & Ireland
Defi nitions: Safety Guidelines
82
83
The definitions below describe the level of severity
for each signal word. Please read the manual and
3
3
pay attention to these symbols.
92
92
3.2
3.2
5.3
7.8
1.5
1.7
WARNING: The declared vibration
emission level represents the main
applications of the tool. However if the
tool is used for different applications,
with different accessories or poorly
maintained, the vibration emission may
differ. This may significantly increase the
exposure level over the total working
period.
An estimation of the level of exposure to
vibration should also take into account
the times when the tool is switched off
or when it is running but not actually
doing the job. This may significantly
reduce the exposure level over the total
working period.
Identify additional safety measures to
protect the operator from the effects of
vibration such as: maintain the tool and
the accessories, keep the hands warm,
organisation of work patterns.
230 V tools
10 Amperes, mains
230 V tools
13 Amperes, in plugs
115 V tools
16 Amperes, in plugs
DANGER: Indicates an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
WARNING: Indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
CAUTION: Indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
NOTICE: Indicates a practice not
related to personal injury which, if
not avoided, may result in property
damage.
Denotes risk of electric shock.
E NG LI SH
21