Further Information; Cold Startup Delay Switch - Axis T92E Housing Serie Manual Del Usuario

Ocultar thumbs Ver también para T92E Housing Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AXIS T92E05/T92E20 User's Guide
10. Install the top cover. Make sure to tighten diagonally opposite bottom cover screws a few turns
at a time until all are tight. This will help ensure that the bottom cover gasket is compressed
evenly. Do not attempt to tighten the screws completely the first time.
Example images: AXIS M1114 Network Camera and AXIS T92E05 Protective Housing
11. Loosen the sunshield adjustment screws and adjust the sunshield to the desired position.

Further information

See the Installation Guide provided with the camera for information on how to assign an IP address,
set the password and access the video stream. The Installation Guide is also available from the Axis
Web site at www.axis.com

Cold Startup Delay Switch

AXIS T92E20 features Arctic Temperature Control, which is enabled by setting the Cold Startup
Delay switch to I (ON). When enabled, this function controls when the camera restarts after a
power cut, when temperatures are below 0 °C (32 °F); the camera is first heated to approximately
0 °C (32 °F) before it initializes. This prevents damage to camera models that include moving parts.
Note: The switch should be disabled for cameras without moving parts, since they do not require this
function, see table on page 8.
AXIS P1343 Network Camera and AXIS T92E20 Outdoor Housing
Page 11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T92e05T92e20T92e serie

Tabla de contenido