Technical data

Nominal voltage:
Nominal power:
Circuit breaker:
Residual current device:
Maximum circuit length of
T2Red is depending on the
start-up temperature:
Max. exposure temperature:
Dimension:
Min. installation temperature:
Min. bending radius:
Approvals:
Fig A: T2Red WITHOUT existing thermal insulation
1. Floor covering
2. Adhesive (underlay paper in case wooden floor)
3. Special (self-levelling) mortar for floor heating systems
(30 – 50 mm)
4. T2Red self-regulating heating cable
5. Metal/mesh (chicken wire) - optional
6. Plastic foil
7. High density polystyrene insulation (thickness 30 – 50 mm)
8. Existing floor (tiles, wood, PVC, ...) without thermal insulation
Fig B: T2Red WITH existing thermal insulation
1. Floor covering
2. Adhesive (underlay paper in case wooden floor)
3. Thin or levelling screed, suitable for underfloor heating (≥ 15 mm)
4. T2Red self-regulating heating cable
5. Existing floor (tiles, wood, PVC, ...) with thermal insulation
The installation of T2Red is described
End of life disposal
The thermostat must be disposed of as Waste Electrical and Electronic
Equipment (WEEE directive) according to local regulations. The rest of
the heating cable system must be disposed of as construction waste.
230 Vac
5 W/m - 15 W/m
(depends on floor structure)
C 10 A
30 mA
100 m @+20°C
85 m @+15°C
75 m @+10°C
60 m @+5°C
65°C
8,7 mm x 6,0 mm
+5°C
35 mm
SEMKO SS 4242411, CE-marked
33
nVent.com/RAYCHEM | 6