Electric heater Aqua compact
Product description
For swimming pools up to 100m
The heater comes with an adjustable thermostat with a temperature range 0-45° C, overheating protection with a maximum
refractive temperature of 60° C and a flow switch that breaks voltage when the water flow is less than 90 l/min.
Casing is made of reinforced thermoplastic, short (3, 6, 9 kW) or long (12, 15, 18 kW).
The heater is available in two different versions: Incoloy 825 or with a titanium power cartridge. Titan is used in aggressive
water, salt water or in pools with chlorine machine/salt chlorinator.
Connections are made of PVC for internal attachments to PVC pipes Ø50 mm.
Technical data
Minimum flow
90 l/min
230V 1-phase (3–6kW)
Voltaget:
230V 3-phase (3–18kW)
400V 3-phase (3–18kW)
Max. pressure:
2,5 bar
Max. temperature:
45°C
Effect
Item no. Incoloy
3kW
141600
6kW
141601
9kW
141602
12kW
141603
15kW
141604
18kW
141605
General installation instruction
The heater should be installed at least 200 mm below normal water level in the pool, see example.
Connection must be made with PVC tube Ø50mm (int. Ø42mm) with at least 200 mm straight length before and after the heater.
Mount the heater so that it is always full of water.
If the heater is placed against combustible material, place a fireproof disc or a similar object between the heater and the wall.
The disc should cover 10 cm outside the heater external wall. The heater must not be covered.
Install the heater in such a way that it can be drained of all water.
The heater must be installed on the return line to the pool after the filter. Do not install a shut-off valve between the heater and
the pool. If a valve is required, install a check valve.
Chlorine, acid or the like dosing should be done AFTER the heater to avoid corrosion.
1.
1.
6.
.
3
Item no. Titan
141600T
141601T
141602T
141603T
141604T
141605T
Installation elvärmare 3-fas
4.
3
5.
7.
Dimensions
3.
8.
Ø50
>200
10.
7
ENGLISH
2.
1. Skimmer
2. Inlet
9.
3. Light
4. JetSwim
5. Main drain
6. Pump
7. Filter
8. Electric heater
9. Check valve
10. Drain
Drawing no: M10879-2
2017-06-07 ASA