PERSONAL PRECAUTIONS

1. Consider having someone close enough by to come
to your aid when you work near a lead-acid battery.
2. Have plenty of fresh water and soap nearby in case
battery acid contacts skin, clothing, or eyes.
Wear ANSI-approved splash-resistant safety
goggles and heavy-duty rubber work gloves
whenever connecting, disconnecting, or working
near battery. Battery acid can cause permanent
blindness.
3. Wear complete eye protection, and protective
clothing. Avoid touching eyes while working near
battery.
4. If battery acid contacts skin or clothing, wash
immediately with soap and water. If acid enters
eye, immediately flood eye with running cold water
for at least 10 minutes and get medical attention
immediately.
5. NEVER smoke or allow a spark or flame near battery.
6. Be extra cautious to reduce risk of dropping a metal
tool onto battery. It might spark or short circuit
battery or other electrical part that may cause
explosion.
7. Remove personal metal items such as rings, bracelets,
necklaces, and watches when working with a lead-
acid battery. A lead-acid battery can produce a short
circuit current high enough to weld a ring or the like to
metal, causing a severe burn.
SPECIFICATIONS
Electrical Rating
Charge Settings
Starter Settings
Battery Cables
Power Cord
8. Use charger for charging a LEAD-ACID battery only.
a. It is not intended to supply power to a low-voltage
b. Do not use battery charger for charging dry-cell
c. People with pacemakers should consult their
9. NEVER charge a frozen battery.
The warnings, precautions, and instructions discussed
in this instruction manual cannot cover all possible
conditions and situations that may occur. It must be
understood by the operator that common sense and
caution are factors which cannot be built into this
product, but must be supplied by the operator.
120VAC / 60Hz / 10A (40A for boost)
6V
2A
40A Boost
12V, 200A
5 second maximum with 180 second rest
6'
Red = Positive
Black = Negative
6' 5"
WWW.FORNEYIND.COM
electrical system other than in a starter motor
application.
batteries that are commonly used with home
appliances. These batteries may burst and cause
injury to persons and damage to property.
physician(s) before use. Electromagnetic fields in
close proximity to heart pacemaker could cause
pacemaker interference or pacemaker failure.
In addition, people with pacemakers should:
• Avoid operating alone.
• Properly maintain and inspect to avoid electrical
shock.
• Properly ground power cord. Ground Fault
Circuit Interrupter (GFCI) should also be
implemented. – it prevents sustained electrical
shock.
2A
10A
40A
Boost
12V
4