Troubleshooting; Possible Cause; Performance Data Sheet - PUR PUN2FS Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting Guide:
Problem
Water leaks between Sump and Head
Water leaks at Push-in Connections
Water leaks at threaded fittings
Water has air bubbles and is cloudy
Either no water flow or very slow.
Water tastes bad or has an odor
Should service be required or you have any questions regarding how to use your PUR product, please contact Customer Service at:
1-877-447-4768 or customerservice@ghpgroupinc.com

Performance Data Sheet:

Note: Read this performance data and compare the capability of this system with your actual water treatment
needs. It is recommended that, before installing the system, you have your water supply tested to determine
your actual water treatment needs.
This system conforms to NSF/ANSI 42, 53 and CSA B483.1 for the specific performance claims as verified and substantiated by test
data. While testing was performed under standard laboratory conditions, actual performance may vary.
This system has been certified by NSF International according to NSF/ANSI 42, 53 and CSA B483.1 for the reduction of substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42 and 53.
PUN2FS with PUNSED and PUNCRBL Filters
Average Influent
Substance
Challenge Concentration
NSF Standard 42/53
Chlorine
2.0 mg/L ± 10%
Particulate Class I
pH 8.5
Lead
0.15 mg/L± 10%
pH 6.5
Flow Rate = 0.5 gpm (1.9 lpm) Capacity = 1,000 gallons (3,780 L) or 6 months
Tested by NSF International according to NSF/ANSI Standard 42, 53 and CSA B483.1.
1
7

Possible Cause

Loose connection of sump and head
O-rings missed or not in right position
Tubing is not pushing in all the way
Tubing end is not cut square
Tubing is cracked or scratched
Loose connection
Air in the system after installation
Inlet valve is closed
Filter cartridge has become clogged
Tubing is kinked
The filter is expended
Percent Reduction
Requirement
≥ 50%
10,000/mL
≥ 85%
0.010mg/L
Solution
Tighten with wrench.
Open sump to check the O-rings.
Push tubing in as far as it will go.
Push tubing out and recut to square.
Simply cut that portion away and reinsert tubing.
Tighten slightly more until leak stops. Do no over-tighten.
Will go away after water runs for a while.
Turn on the valve.
Replace the filter cartridge.
Check the tubing and make smooth line.
Replace the filter cartridge.
Percent Reduction
1
97.4%
99.6%
99.7%
99.7%
Manufactured and warranted by GHP Group Inc.
USA: 6440 W. Howard St. Niles, IL 60714-3302