Fueling The Heater:
Kerosene (K-1)
For optimal performance of this heater, it is
strongly suggested that K-1 kerosene be used,
especially in temperatures lower than 26°F
(-3°C). K-1 kerosene has been refined to virtually
eliminate contaminants, such as sulfur, which can
cause a rotten egg odor during the operation
of the heater. Using diesel fuel can cause excess
soot production. Do not use Bio-Diesel as this
fuel will damage your heater's seals and filter.
- CSA certified for use with K-1 kerosene, no.
1 & no. 2 diesel, JP8/Jet A Fuel, no. 1 and no.
2 fuel oil.
DANGER
OR OPERATING. FIRE OR EXPLOSION
COULD RESULT.
CAUTION
WAYS FILL THE TANK OUTDOORS. BE
SURE THAT THE HEATER IS ON LEVEL
GROUND WHEN FUELING, AND NEVER
OVERFILL THE TANK.

WARNING

DO NOT use any fuel that is not approved
above.
- NEVER use fuel such as, benzene, alcohol, white
glass, camp stove fuel, paint thinners, or other oil
compounds in this heater. THESE ARE VOLATILE
FUELS THAT CAN CAUSE A FIRE OR EXPLOSION.
- NEVER store kerosene in the living space. Kerosene
should be stored in a well ventilated area outside
the living area.
- NEVER store kerosene in direct sunlight or near a
source of heat.
- NEVER use kerosene that has been stored from
one season to the next. Kerosene deteriorates
over time. OLD KEROSENE WILL NOT BURN
PROPERLY IN THIS HEATER.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
OPERATION
NEVER REFUEL
THIS HEATER
WHILE IT IS HOT
NEVER FILL
THE FUEL TANK
INDOORS. AL-
DO NOT USE
GASOLINE OR
CRANKCASE
DRAININGS.
NOTE: Kerosene should only be stored in a blue
container that is clearly marked "Kerosene."
Never store kerosene in a red container. Red is
associated with gasoline.
Ventilation:
DANGER
CARBON MONOXIDE POISONING MAY
LEAD TO DEATH!
- Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in well
ventilated areas.
- Refer to Safety Information on page 3 for
information about Carbon Monoxide
Poisoning.
- ALWAYS provide a fresh air opening in the heated
space of at least three square feet (2,800 sq. cm)
for each 100,000 Btu / Hr. (29 kW) of heater
output. Provide a larger opening if more heaters
are being used.
Minimum Ventilation Opening Needed
45-KFA
1.4 ft.²
1250 cm²
Minimum Ventilation Opening Needed
190T-KFA
5.7 ft.
2
5290 cm
6
Kerosene Forced Air Heater User's Manual
80T-KFA
140T-KFA
2.4 ft.²
4.2 ft.²
2230 cm²
3902 cm²
215T-KFA
6.5 ft.²
5990 cm²
2

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Rem-80t-kfa-oRem-140t-kfa-oRem-190t-kfa-oRem-215t-kfa-o

Tabla de contenido