Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved
fuel until needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a
three prong (grounded) extension cord that
is at least 6 feet long and is a minimum of 14
AWG rating.
Model 45-KFA:
1. Complete steps 1-3 above.
2. Move power switch to "On" position. The
power indicator light will illuminate and the
heater will ignite.
Stopping / Restarting Heater:
- To stop the heater, move the power switch to the
"Off" position and unplug the power cord.
- To restart the heater; wait 10 seconds and follow
ignition steps.
TIP: If the heater does not ignite; move
switch to "Off" position, check steps 1-3
above and then move switch to "On" position.
Models 80T-KFA - 215T-KFA:
1. Complete "starting heater ignition" steps 1-3
above
2. Turn thermostat control knob to desired
temperature setting. The thermostat set range
is from 40 ºF to 110 ºF.
3. Move power switch to "On" position. The
power indicator light and room temperature
display will illuminate and heater will ignite.
NOTE: 45-80T-KFA models do not have a room
temperature display feature.
The room temperature display will indicate the
following:
- When the temperature is less than 0 ºF the
display says "LO".
- When the temperature is more that 99 ºF the
display says "HI".
- Between 0 F and 99 F the display shows actual
temperature.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
OPERATION (CONT.)
Stopping / Restarting Heater:
- To stop the heater, move the power switch to the
- To restart the heater; wait 10 seconds and follow
control knob to a higher setting until the heater
ignites. If the heater does not ignite; move switch
to "Off" position, check steps 1-3 above and then
move switch to "On" position.
Long Term Storage:
Models 45-KFA - 80T-KFA:
1. Use an approved siphon to drain fuel through the
Models 140T-KFA - 215T-KFA:
1. Drain fuel through the drain bolt in the bottom
2. To remove the drain bolt, unscrew
3. Using a small amount of kerosene, rinse and
4. To replace the drain bolt; push the drain head
IMPORTANT: Never store leftover kerosene
between seasons, using old fuel can damage
heater.
7
"Off" position and unplug the power cord.
ignition steps.
TIP: If the heater does not ignite, the
thermostat may be set too low. Turn the
fuel cap opening.
of the fuel tank.
counterclockwise.
swirl the kerosene inside of the fuel tank,
empty the tank fully.
fully into the drain hole and screw clockwise.
Kerosene Forced Air Heater User's Manual