Multiplex MULTIswitch FLEXX Manual Del Usuario página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6
S
ETTINGS
6.1
Settings for SMART SX FLEXX remote control
The factory settings of the MULTIswitch FLEXX are
selected so that the three switching channels can be
operated using the SMART SX FLEXX transmitter.
Switching
Actuator in the
channel
SMART SX FLEXX
transmitter
1
Left vertical rocker
switch
2
Right vertical rocker
switch
3
Left stick button
6.2
Assignment of free servo channels
If you are using a remote control with freely assignable
servo channels, you can control the MULTIswitch FLEXX
with the factory settings as follows:
Servo
MULTIswitch FLEXX switching
channel
channel
5
6
7
6.3
Settings using MULTIPLEX Launcher
You can customize MULTIswitch FLEXX according to
your requirements using the free MULTIPLEX Launcher
PC software.
The MULTIPLEX Launcher PC software is available at
http://www.multiplexrc.de.
You need the following accessories to connect to a PC:
• MULTIPLEX PC USB adapter #85149
You can specify the following settings for each switching
channel:
• Servo channel
• Switching threshold and direction
• Type of switching function
• Load control: Duration, blink mode, flash mode
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten (Gölshausen) • www.multiplex-rc.de
Operating Instructions
MULTIswitch FLEXX
Function
on / off
on / off
Figure 5 Windows software MULTIPLEX Launcher
Press button
to switch on /
off
7
Problem:
MULTIswitch FLEXX is not receiving any data via the
SRXL cable (the LED remains off).
Possible causes and solutions:
• MULTIswitch FLEXX must be restarted (e.g. after
1
2
• If you are using a MULTIPLEX telemetry receiver, the
3
Problem:
The LED for receiving data lights up, but no power is
being supplied to the loads.
Possible causes and solutions:
• Jumper U(Bat) is disconnected.
• No voltage source is connected to the terminal U(Bat).
• The
8
E
RRORS AND SOLUTIONS
operation on the PC): Disconnect the supply voltage
and reconnect it.
SRXL output must be activated first on the receiver
(e.g. using the MULTIPLEX PC USB adapter #85149
and
MULTIPLEX
Launcher
MULTImate).
servo
assignment
transmitter does not match the settings in the
MULTIswitch FLEX.
A
CCESSORIES
MULTIPLEX
#85149
:
or
using
#82094
on
the
remote
control
PC
USB
adapter
Page 3/4

Publicidad

Tabla de contenido
loading

Tabla de contenido