Special Programming Art. 4880 And 4881 - Comelit Group GENIUS-KIT MT KIT 08 Hoja Técnica

Kit video
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Special programming Art. 4880, 4881
On Art. 4880 and 4881 it is possible to carry out a series of special
programming operations according to the various system requirements.
1. On articles 4880, 4881 remove the two jumpers in the bottom right hand
corner (Fig. 1).
2. Enter programme mode by inserting one of the jumpers in position JP4 (Fig.
2).
3. On the DIP switches of the article, set the relative code for the function you
want to programme (Fig. 3). Use the following table as a reference.
10 seconds (factory setting)Reset wait time
1 secondLock confirmation tone disabling
Lock time:2 seconds (factory settings)
Activation of lock confirmation tone
Lock time:8 seconds
Sending single call (factory setting)
Sending repeated call 3 times
Door opener active even with no call (factory setting)
Door opener only enabled for the user called
Reset of all the factory settings
4. Confirm the function set by inserting jumper JP5 (Fig.4), wait until a
confirmation tone sounds, then remove jumper JP5 again.
5. After completing the procedure, remove the jumpers from positions JP4, JP5
and restore them to their original position (Fig. 5)
In order to program another parameter, repeat this procedure from step 1 to
step 5.
Dip switches to ON
1,2,5,6,7,8
3,5,6,7,8
1,3,5,6,7,8
2,3,5,6,7,8
1,2,3,5,6,7,8
4,5,6,7,8
1,4,5,6,7,8
3,4,5,6,7,8
1,3,4,5,6,7,8
2,3,4,5,6,7,8
MT KIT 08
Reset wait time
243
244
245
246
247
248
249
252
253
254
17
MT KIT 08

Publicidad

Tabla de contenido
loading

Productos relacionados para Comelit Group GENIUS-KIT MT KIT 08

Tabla de contenido